LIMITED WARRANTY

Sta-Rite warrants to the original consumer of the products listed below, that they will be free from defects in material and work-
manship for the Warranty Period from the date of original installation or manufacture as noted.

Product

Warranty Period

Water Systems Products – jet pumps,

whichever occurs first:

small centrifugal pumps, submersible pumps

1 year from date of original installation, or

and related accessories

2 years from date of manufacture

Con-Aire

®

Tanks

5 years from date of original installation

Epoxy-Line Tanks

3 years from date of original installation

Sump/Sewage/Effluent Products

1 year from date of original installation, or
2 years from date of manufacture

Our warranty will not apply to any product that has been subject to negligence, misapplication, improper installation or main-
tenance. In the event a three phase submersible motor is operated with single phase power through a phase converter, or if three-
leg ambient compensated, extra-quick trip overload relays of recommended size are not used, our warranty is void.

Buyer’s only remedy and Sta-Rite’s only duty is to repair or replace defective products (at Sta-Rite’s choice). Buyer agrees to pay
all labor and shipping charges associated with this warranty and to request warranty service through the installing dealer as soon
as a problem is discovered. If warranty service is requested more than 30 days after the Warranty Period has ended, it will not
be honored.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WAR-
RANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD PROVIDED HEREIN.

Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on
the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth spe-
cific legal rights and obligations, however, additional rights may exist, which may vary from state to state.

Supersedes all previous publications.

Sta-Rite Industries, Inc. 293 Wright St., Delavan, WI  53115

Page

General Safety .....................................................................................................2

Warranty ..............................................................................................................3

Installation ........................................................................................................4-7

Electrical...........................................................................................................8-9

Operation .....................................................................................................10-11

Maintenance.................................................................................................12-13

Troubleshooting..................................................................................................14

Repair Parts  .................................................................................................15-16

Содержание MSC-6

Страница 1: ...umps 20 100 80 60 40 2001 Sta Rite Industries Inc PRINTED IN U S A S757 1 Rev 10 31 01 293 Wright Street Delavan WI 53115 MS Series Installation Operation Parts For further operating installation or m...

Страница 2: ...GENERAL SAFETY Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before hand...

Страница 3: ...duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the instal...

Страница 4: ...equirements usually pipe must by 12 below frost line and pump must be insulated Step 4 Be sure all pipes and foot valve are clean and in good shape Step 5 No air pockets in suction pipe Step 6 No leak...

Страница 5: ...at least 10 to 20 feet below the lowest water level with pump running if possi ble but always at least five feet from the bottom of the well Step 8 Tighten all hose clamps securely on plastic pipe Use...

Страница 6: ...e well see Figure 8 Step 4 To properly seat the cup seals after the ejector is correctly posi tioned move the assembly up and down slightly Water pressure in the casing will then soak the cup seals se...

Страница 7: ...pump and to AVC on tank See installation instructions provid ed with tank and AVC for details PRECHARGED TANK CONNECTION When a precharged tank is used no AVC is necessary See Figure 10 for typical p...

Страница 8: ...oltage motor Connect power supply as shown for your type of switch and your supply voltage Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Volts A L...

Страница 9: ...ure 12 The ground wire must be a solid copper wire at least as large as the power sup ply wires Step 2 There must be a solid metal connection between the pressure switch and the motor for motor ground...

Страница 10: ...more as ejector and pump prime IF NO PRESSURE OR NO WATER REPEAT Step No 1 above two or three times to remove entrapped air from the suction pipes Step 3 If after priming pump several times no water...

Страница 11: ...In this case operate pump with regulator valve open HOW TO HANDLE A GASEOUS WELL In some areas well water contains gases which must be allowed to escape before the water is used To deliver gas free w...

Страница 12: ...a small screwdriver or thin bladed chisel in between the intermediate volute and the pump adapter in two or three places around the pump to separate the castings Figure 20 Do not mar the sealing surfa...

Страница 13: ...e up with the water passages in the volutes Step 9 Install the intermediate volute aligning it with the mark made before disassembly Use the long cap screws to check this align ment It cannot be stres...

Страница 14: ...k valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are Raise foot valve and or strainer above bottom of water source buried...