7
TABLE III - RECOMMENDED FUSING AND WIRING DATA – P6RA MODELS
Serv. to Motor - Dist. in Ft. (M)
Motor
Branch Fuse
Max Load
Voltage/
0-100'
101-200'
201-300'
HP
Rating Amps*
Amps
Hz/Phase
(0-30 M)
(30-60 M) (60-90 M)
P6RA Models:
1
20/15
15.3/7.6
115/230/60/1 12/14(3/2) 8/14(8.4/2) 6/14(14/2)
1-1/2
30
19.2
115/60/1
10(5.5)
8(8.4)
6(14)
1-1/2
15
9.6
230/60/1
14(2)
14(2)
12(3)
1-1/3
15
12.0
230/60/1
14(2)
12(3)
12(3)
2
15
12.0
230/60/1
14(2)
14(2)
12(3)
P6RA 2-Speed Models:
1-1/2
15
9.2/2.5
230/60/1
14(2)
14(2)
12(3)
2
15
10.1/3.7
230/60/1
14(2)
14(2)
12(3)
* Time delay fuses are recommended instead of standard fuses in any motor circuit.
Wire
Size
AWG
(mm
2
)
}
TABLE II - RECOMMENDED FUSING AND WIRING DATA – P6EA MODELS
Serv. to Motor - Dist. in Ft. (M)
Motor
Branch Fuse
Max Load
Voltage/
0-100'
101-200'
201-300'
HP
Rating Amps*
Amps
Hz/Phase
(0-30 M)
(30-60 M) (60-90 M)
1
20
13.8
115/60/1
12(3)
10(5.5)
8(8.4)
1-1/2
25
16.0
115/60/1
12(3)
8(8.4)
6(14)
1
15
6.9
230/60/1
14(2)
14(2)
14(2)
1-1/2
15
8.0
230/60/1
14(2)
14(2)
12(3)
1-3/4
15
10.4
230/60/1
14(2)
12(3)
12(3)
2
15
10.4
230/60/1
14(2)
12(3)
12(3)
2-1/2
15
11.2
230/60/1
14(2)
12(3)
12(3)
* Time delay fuses are recommended instead of standard fuses in any motor circuit.
Wire
Size
AWG
(mm
2
)
}
Wire
Size
AWG
(mm
2
)
}
TABLE I - RECOMMENDED FUSING AND WIRING DATA – P6E MODELS
Serv. to Motor - Dist. in Ft. (M)
Motor
Branch Fuse
Max Load
Voltage/
0-100'
101-200'
201-300'
HP
Rating Amps*
Amps
Hz/Phase
(0-30 M)
(30-60 M) (60-90 M)
P6E Models:
1/2
15
11.0
115/60/1
14(2)
10(5.5)
8(8.4)
3/4
20
13.8
115/60/1
12(3)
10(5.5)
8(8.4)
1
25
16.0
115/60/1
12(3)
8(8.4)
6(14)
1/2
15
5.5
230/60/1
14(2)
14(2)
14(2)
3/4
15
6.9
230/60/1
14(2)
14(2)
14(2)
1
15
8.0
230/60/1
14(2)
14(2)
14(2)
1-1/2
15
10.4
230/60/1
14(2)
12(3)
12(3)
2
15
11.2
230/60/1
14(2)
12(3)
12(3)
3
25
15.8
230/60/1
12(3)
12(3)
10(5.5)
* Time delay fuses are recommended instead of standard fuses in any motor circuit.