background image

12

Motor No.

Impeller

Diffuser

Model No.

HP

(Key No. 1)

(Key No. 10)

(Key No. 11)

115/230 Volt

P6E6C-204L

1/2

AE100CHL

C105-238PX

C1-271P1

P6E6D-205L

3/4

AE100DHL

C105-238P

C1-271P1

P6E6E-206L

1

AE100EHL

C105-238PB

C1-271P1

P6EA6E-205L

1

AE100ELL

C105-238P

C1-271P1

P6RA6E-205L

1

A100ELL

C105-238P

C1-271P1

P6EA6F-206L

1

1

2

AE100FLL

C105-238PB

C1-271P1

P6RA6F-206L

1

1

2

A100FLL

C105-238PB

C1-271P1

230 Volt

P6E6F-207L*

1

1

2

AE100FHL

C105-238PDBA

C1-271P

P6EAA6F-216L*

1

3

4

AE100F5LL

C105-238PDCA

C1-271P

P6RAA6F-216L*

1

3

4

A100F5LL

C105-238PDCA

C1-271P

P6E6G-208L*

2

AE100GHL

C105-238PEBA

C1-271P

P6EA6G-207L*

2

AE100GLL

C105-238PDBA

C1-271P

P6RA6G-207L*

2

A

100GHL

C105-238PDBA

C1-271P

P6EAA6G-208L*

2

1

2

AE100G5LL

C105-238PEBA

C1-271P

P6E6H-209L*

3

AE100HLL

C105-238PLA

C1-271P

2-Speed

P6RA6YF-206L**

1

1

2

–1/4

A100FLL-Y

C105-238PBA

C1-271P

P6RA6YG-207L*

2–1/3

A100GLL-Y

C105-238PDBA

C1-271P

Parts are common to all models listed except as noted; 

Key Nos. 1, Motor; 10, Impeller; and 11, Diffuser are listed below.

Key

Part Part 

No.

Description

Qty.

No.

1

Motor

1

Chart at Right

2

#10-32x1/2” Screw 

1

U30-692SS

2A

Lock Washer 

1

U43-22SS

3

Bonding Lug

1

U17-568

4

Water Slinger

1

17351-0009

5

Seal Plate Kit 

(Incl. Key Nos. 6, 7)

1

C203-194P

6

O-Ring

1

U9-228A

7

Shaft Seal

1

37400-0028S

8

Clamp Knob

1

C19-37A

9

Clamp

1

WC36-22

10

Impeller

1

Chart at Right

10A

Impeller Screw O-Ring

1

35505-1426

10B

Impeller Screw 

1

Chart at Right

11

Diffuser

1

Chart at Right

12

Diffuser O-Ring

1

U

9-374

13

#8 Lock Washer

5

U43-21SS

14

Screw (w/C1-271P

Diffuser)

5

U30-922SS

14

Screw (w/C1-271P1

Diffuser)

5

U30-542SS

15

Tank Body Assembly****

1

17307-0110S

16

Trap Cover Assembly**

1

17307-0111S

17

Trap O-Ring

1

35505-1440

18

Basket

1

C8-58P

19

1/4” NPT Drain Plug 

2

U178-920P

20

Base Washer

2

U43-41SS

21

Base Screw

2

U30-918SS

22

Base w/Motor Pad***

1

C104-78P

23

Motor Pad

1

C35-43

24

3/8-16x1”

Hex Hd. Screw 

4

U30-74SS

Voltage Sticker - 230 Volts

(Single voltage models only)

U27-68

Voltage Sticker - 115/230 Volts

(Dual voltage models only)

U27-153

Tag, “CAUTION, WARNING

(bonding)”

61002-0002

Decal, “Do not overtighten...”

U27-644

Nameplate

32155-7117

REP

AIR P

A

R

T

S LIST

*Uses Key No. 10B Impeller Screw No. 37337-6080. 

** Uses Key No. 10B Impeller Screw No. 37337-6081.

N

ot illustrated.

**

Includes Trap Cover, Trap Ring and Trap Cover O-Ring.

***

Model P6E6H uses Base No. C104-79P and

Motor Pad No. C35-44.

****

Includes Trap Body, Basket, Drain Plugs, and 

Trap Cover Assembly.

P6E, P6EA, P6RA

MAX-E-PRO

TM

POOL PUMP

1/2 thr

ough 3 HP Models

For quick disconnect pipe connections,

purchase separately:

Pkg. 188 2" Slip 1/2 Union Kit or

Pkg. 189 2" NPT 1/2 Union Kit.

Includes 2 each:

U11-200P Union Collar

U9-362 O-Ring

U11-196P 2" Slip adapter or

U11-199P 2" NPT adapter.

Bo

x A

Содержание MAX-E-PRO P6E

Страница 1: ...mbers Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S691 Rev 11 18 05 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life ...

Страница 2: ...d warns about hazards that can cause death serious personal injury or major property damage if ignored warns about hazards that will or can cause minor personal injury or property damage if ignored NOTICE indicates special instructions not related to hazards Carefully read and follow all safety instructions in this manual and on equipment Keep safety labels in good condition replace if missing or ...

Страница 3: ...bient temperature whenever the pump is running Be solid Level Rigid Vibration free Non com bustible To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Allow use of short direct suction pipe To reduce friction losses Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be ...

Страница 4: ...slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pipes Fittings Fittings restrict flow for best efficiency use fewest possi ble fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical ...

Страница 5: ...one main drain suction fitting is completely blocked The flow through the remaining main drain s must com ply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications ELECTRICAL Ground motor before connecting to electrical power supply Failure to ground motor can cause se vere or fatal electrical shock hazard Do not gro...

Страница 6: ...pening on end of motor to prevent dirt bugs etc from entering motor Risk of dangerous or fatal electrical shock Be sure that power to the motor circuit is off before working on wiring wiring connections or motor Re in stall the motor end cover and all other wiring covers be fore turning on the power 1 Turn off power 2 Remove the motor end cover To Wire a Single Speed Single Voltage Motor There are...

Страница 7: ...30 60 M 60 90 M 1 20 13 8 115 60 1 12 3 10 5 5 8 8 4 1 1 2 25 16 0 115 60 1 12 3 8 8 4 6 14 1 15 6 9 230 60 1 14 2 14 2 14 2 1 1 2 15 8 0 230 60 1 14 2 14 2 12 3 1 3 4 15 10 4 230 60 1 14 2 12 3 12 3 2 15 10 4 230 60 1 14 2 12 3 12 3 2 1 2 15 11 2 230 60 1 14 2 12 3 12 3 Time delay fuses are recommended instead of standard fuses in any motor circuit Wire Size AWG mm2 Wire Size AWG mm2 TABLE I RECO...

Страница 8: ... original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silicone based lubricant Clean and inspect O Ring reinstall on trap Replace trap cover and handle ring on trap turn handle ring clockwise to tighten cover NOTICE Tighten trap cover handle ring by hand only no wrenches Pump should prime ...

Страница 9: ...astic For outdoor unprotected installations 1 Gravity drain system as far as possible 2 Protect areas which retain water with non toxic propy lene glycol antifreeze RV antifreeze 3 Enclose entire system in a weatherproof enclosure 4 To avoid condensation corrosion damage allow venti lation do not wrap system in plastic 5 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C Star...

Страница 10: ...nt press ce ramic seat into seal plate firmly and squarely with finger pressure Figure 5 2 If ceramic seat will not locate properly remove it place face up on bench and reclean cavity Ceramic seat should now locate 3 If seat still will not locate properly place a cardboard washer over the polished face and use a piece of 3 4 19mm standard pipe for pressing purposes NOTICE Be sure not to scratch or...

Страница 11: ...logged follow steps 1 through 7 under Removing Old Seal Page 10 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 10 for re assembly 7 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Page 12 8 Pump may be trying to push too high a column of water If so a higher head pump is needed Electrical 9 Pump may be running too slowly...

Страница 12: ... Shaft Seal 1 37400 0028S 8 Clamp Knob 1 C19 37A 9 Clamp 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller Screw O Ring 1 35505 1426 10B Impeller Screw 1 Chart at Right 11 Diffuser 1 Chart at Right 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 Screw w C1 271P Diffuser 5 U30 922SS 14 Screw w C1 271P1 Diffuser 5 U30 542SS 15 Tank Body Assembly 1 17307 0110S 16 Trap Cover Assembly 1 17...

Страница 13: ...13 1 5 6 11 12 13 See Box A See Box A 16 18 17 19 15 14 10 10A 7 8 9 3 4 2 2A 21 22 23 24 20 10B 4285 1102 P6E P6EA P6RA MAX E PRO TM POOL PUMP 1 2 through 3 HP Models ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...ulbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties relate to the original consumer purchaser Purchaser only Sta Rite Industries shall have the option to re pair or replace the defective product at its sole discretion Purchasers must pay all labor an...

Отзывы: