background image

2

SWIMMING POOL PUMP 

To avoid unneeded service calls, prevent possible injuries, and get the most
out of your pump, READ THIS MANUAL CAREFULLY!

The Sta-Rite ‘JWP’ Series Above Ground Pool Pump:

• Is designed to circulate water in swimming pools.
• Is an excellent performer; durable, reliable.

Table of Contents

Warranty.......................................................................................................2

Safety Instructions  ........................................................................................3

Specifications/Dimensions ............................................................................4

Installation.................................................................................................5-6

Electrical.......................................................................................................7

Operation .....................................................................................................8

Pump Service................................................................................................9

Storage/Winterizing ....................................................................................10

Troubleshooting Guide ...............................................................................11

Repair Parts List ..........................................................................................12

LIMITED WARRANTY

Pumps, filters, spa systems, skimmers, underwater lights (except bulbs), accessories and fittings manufactured by Sta-
Rite are warranted to be free of defects in material and workmanship for one (1) year from date of installation.
HRPB, DEPB and System 3 are warranted against defects in material and workmanship for a period of ten (10) years
from date of installation. Internal filter components and valves are warranted for a period of one (1) year from date
of installation.
The foregoing warranties relate to the original consumer purchaser (“Purchaser”) only.  Sta-Rite shall have the op-
tion to repair or replace the defective product, at its sole discretion. Purchasers must pay all labor and shipping
charges necessary to replace the product covered by this warranty. Requests for warranty service must be made
through the installing dealer. This warranty shall not apply to any product that has been subject to negligence, mis-
application, improper installation or maintenance, or other circumstances which are not in Sta-Rite’s direct control.
This warranty sets forth Sta-Rite’s  sole obligation and Purchaser’s exclusive remedy for defective products.
STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR CONTINGENT DAMAGES
WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE
EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how
long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state to state.
Supersedes all previous publications.

Sta-Rite Industries, Inc., 600 S. Jefferson St., Waterford, WI 53185

Содержание JWPD-075

Страница 1: ...WI 53185 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Orlando FL Union City TN Delavan WI Mississauga Ont 1995 Sta Rite Industrie...

Страница 2: ...t its sole discretion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dea...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...breaker sizes TABLE I RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 HZ MOTORS Branch Wire Gauge Size Model Motor Voltage Full Load Circuit Breaker Dist in Ft M Service Motor Temp No H P Hz P...

Страница 5: ...e pipe dope pipe dope will cause stress cracking in the pump See Figure 4 NOTICE Pump suction and discharge connections have molded in thread stops DO NOT try to screw pipe in beyond these stops Tight...

Страница 6: ...slope suction pipe slightly upward toward the pump See Figure 8 NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pi...

Страница 7: ...onductor No 8 AWG 8 4 sq mm or larger Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool sp...

Страница 8: ...y each time it is re moved Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Use a wrench o...

Страница 9: ...Figure 12 Do not damage impeller surface where drive ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 13 re move seal plate and use a screwdriver to tap ceramic s...

Страница 10: ...pump 1 Close all valves on suction and return piping 2 Remove drain plug in bottom of volute 3 Drain all piping exposed to freezing temperatures 4 Be sure no airlocks are holding water in the system...

Страница 11: ...piping is too small 5 Check and clean pool filter 6 Consult dealer installer or service representative D CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY 1 Breaker must be of adequate capacity 2 For GFC...

Страница 12: ...1 C3 139P1 15 Trap Cover O Ring 1 U9 229 16 Trap Basket 1 C108 33P 17 Drain Plug 1 4 NPT 2 U178 920P 18 Capscrew 5 16 18x1 1 4 4 U30 64SS 19 Lock Washer 5 16 4 U43 11SS 20 Flat Washer 5 16 4 U43 41SS...