Table of Contents
3
Thank you for purchasing a top quality, factory tested pump.
Page
General Safety .....................................................................................................2
Installation ........................................................................................................4,5
Connecting Discharge Piping...............................................................................6
Electrical ...........................................................................................................7,8
Preparing To Start The Pump................................................................................9
Troubleshooting..................................................................................................10
Repair Parts .......................................................................................................11
Warranty ............................................................................................................12
Model
Disch.
GPH at depth to water
Shut Off
HP
PSI
5 Ft.
10 Ft.
15 ft.
20 Ft.
25 Ft.
Pressure PSI
HNC-L
30
15.0
13.0
11.6
8.7
6.9
1/2 HP
40
12.5
11.4
10.1
8.2
6.8
70
50
8.0
6.8
6.1
4.8
3.5
HND-L
30
21.4
19.1
16.5
13.3
9.5
3/4 HP
40
20.8
18.7
15.8
13.2
9.3
67
50
13.5
11.6
10.1
7.4
2.4
HNE-L*
30
28.5
25.0
21.4
17.4
12.6
1 HP
40
28.3
24.4
21.0
17.2
12.3
67
50
21.5
18.3
10.9
3.1
1.6
Performance Chart
* Performance taken with 1-1/2 NPT suction pipe.
Model
Disch.
GPH at depth to water
Shut Off
HP
PSI
5 Ft.
10 Ft.
15 ft.
20 Ft.
25 Ft.
Pressure PSI
HNDX
30
15.0
13.0
11.6
8.7
6.9
3/4 HP
40
12.5
11.4
10.1
8.2
6.8
70
50
8.0
6.8
6.1
4.8
3.5
HNEX
30
21.4
19.1
16.5
13.3
9.5
1 HP
40
20.8
18.7
15.8
13.2
9.3
67
50
13.5
11.6
10.1
7.4
2.4
HNFX
30
28.5
25.0
21.4
17.4
12.6
1-1/2 HP
40
28.3
24.4
21.0
17.2
12.3
67
50
21.5
18.3
10.9
3.1
1.6
Performance Chart for Export Models