background image

12

LIMITED WARRANTY

Sta-Rite Industries, Inc., warrants to the original consumer of the products listed below, that they will be free from
defects in material and workmanship for the Warranty Period from the date of original installation or manufacture
as noted.

Product

Warranty Period

Water Systems Products – jet pumps,

whichever occurs first:

small centrifugal pumps, submersible pumps

1 year from date of original installation, or

and related accessories

2 years from date of manufacture

Hydro-Flow Filters

1 year from date of purchase

Signature 2000 Fibrewound Tanks

5 years from date of original installation

Pro-Source Steel Pressure Tanks

5 years from date of original installation

Pro-Source Epoxy-Line Tanks

3 years from date of original installation

Sump/Sewage/Effluent Products

1 year from date of original installation, or
2 years from date of manufacture

Our warranty will not apply to any product that has been subject to negligence, misapplication, improper instal-
lation or maintenance. In the event a three phase submersible motor is operated with single phase power
through a phase converter, or if three-leg ambient compensated, extra-quick trip overload relays of recom-
mended size are not used, our warranty is void.

Buyer’s only remedy and Sta-Rite Industries, Inc.’s only duty is to repair or replace defective products (at Sta-
Rite Industries, Inc.’s choice). Buyer agrees to pay all labor and shipping charges associated with this warranty
and to request warranty service through the installing dealer as soon as a problem is discovered. If warranty ser-
vice is requested more than 30 days after the Warranty Period has ended, it will not be honored.

STA-RITE INDUSTRIES, INC. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CON-
TINGENT DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES.
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE WAR-
RANTY PERIOD PROVIDED HEREIN.

Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of
limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply.
This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may vary
from state to state.

Supersedes all previous publications.

Sta-Rite Industries, Inc. 293 Wright St., Delavan, WI  53115

Содержание HN series

Страница 1: ...mps Tank Systems 2001 Sta Rite Industries Inc PRINTED IN U S A S410 Rev 6 13 01 293 Wright Street Delavan WI 53115 HN Series Installation Operation Parts For further operating installation or maintena...

Страница 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Страница 3: ...5 13 3 9 5 3 4 HP 40 20 8 18 7 15 8 13 2 9 3 67 50 13 5 11 6 10 1 7 4 2 4 HNE L 30 28 5 25 0 21 4 17 4 12 6 1 HP 40 28 3 24 4 21 0 17 2 12 3 67 50 21 5 18 3 10 9 3 1 1 6 Performance Chart Performance...

Страница 4: ...s large as the suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the...

Страница 5: ...pipe The suction pipe should be at least as large as the suction port on the pump Step 2 Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works freely Use teflon tape...

Страница 6: ...ize must be at least as large as the discharge port Step 3 Remove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port see Figure 5 Run tubing from the pump s AVC port see Figure 5 to the p...

Страница 7: ...ngle voltage motor Connect power supply as shown for your type of switch and your supply voltage Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Vol...

Страница 8: ...completed the wiring for your pump Please go to Page 9 for startup preparations DISTANCE IN FEET METERS FROM MOTOR TO SUPPLY 0 100 101 200 201 300 301 400 401 500 Max Load Branch Fuse 0 30 31 61 62 91...

Страница 9: ...to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime Step 4 After the pump has built up pressure in the system and shut off check the pressure...

Страница 10: ...are Raise foot valve and or strainer above bottom of water source buried in sand or mud Clean foot valve and strainer Water level is too low for shallow well A deep well jet package may be needed ove...

Страница 11: ...mp Body Assembly 1 N176 43B N176 43B N176 44 N176 44 N176 44A N176 44A 11A Venturi 1 N32P 75 N32P 75 N32P 64 N32P 64 N32P 65 N32P 65 11B Nozzle 1 N34P 21 47 N34P 21 47 J34P 44 54 J34P 44 54 J34P 44 54...

Страница 12: ...ick trip overload relays of recom mended size are not used our warranty is void Buyer s only remedy and Sta Rite Industries Inc s only duty is to repair or replace defective products at Sta Rite Indus...

Отзывы: