OPERATION

Priming Pump:

NEVER run pump dry! Running pump dry may damage seals, causing
leakage and flooding! Fill tub to 2 inches (51mm) above top of jets 

before starting system.

Do not block pump suction! To do so with body may cause severe or
fatal injury. Small children using spa must ALWAYS have close adult 

supervision!

NOTICE: 

Do not block jets! To do so may flood area causing damage to

equipment and water damage to surrounding area.

Water:

Keep water temperature at 104°F (40°C) or below.

Age or health conditions may require a lower temperature; consult a physi-
cian for more information.

If in doubt, start at a lower temperature and gradually increase it according to
your experience.

Keep an accurate thermometer in bath; check it before getting in.

Do not use or allow the use of the tub by anyone using alcohol or
drugs. The effects of hot water, alcohol and/or drugs can cause dizzi-

ness and falling, loss of consciousness, or heart attack.

A long bath in hot water may cause hyperthermia (too much heat in
the body) which can be fatal. Some symptoms of hyperthermia are:

• Nausea
• Dizziness
• Fainting

If these symptoms appear while in the spa, GET OUT AT ONCE!
Cool the body at once with cold towels or a cool shower.
Call a doctor if symptoms do not go away.

Too much heat
can cause nausea,
dizziness,
fainting, or death.

Check temperature.
before using tub.

Hazardous suction.
Can trap hair or
body parts, causing
severe injury
or death.

Do not block
suction.

Содержание Dura Jet JSACLC-A

Страница 1: ...SAYELC LA JSAEFLC A JSAYFLC 230A JSYE 100 JSYF 150 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Missi...

Страница 2: ...he Sta Rite JT Series Tub Pump Is designed to circulate hot water in jetted tubs Is an excellent performer durable reliable Drains completely to assure sanitation meet IAPMO standards Table of Content...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Страница 4: ...Piping Use flexible or rigid PVC pipe for connections to pump Use at least 1 1 2 IPS pipe Fittings restrict flow for best efficiency use fewest possible fittings Unions are provided Use as follows for...

Страница 5: ...rect wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit break...

Страница 6: ...OMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 Hz MOTORS Branch AWG mm2 Wire Gauge Size Full Circuit Dist in Ft M Service to Motor Model Motor Load Breaker 0 100 101 200 201 300 Temp No HP Volts...

Страница 7: ...erature and gradually increase it according to your experience Keep an accurate thermometer in bath check it before getting in Do not use or allow the use of the tub by anyone using alcohol or drugs T...

Страница 8: ...e ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage seal cav...

Страница 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Страница 10: ...3 Not illustrated JSAFLC A JSAEFLC A only REPAIR PARTS LIST DURA JETTM and MAX E JETTM SPA PUMP 1 2 through 1 1 2 HP Models Parts are common to all models listed except as noted Key Nos 1 Motor and 9...

Страница 11: ...s Blocked fittings will cause poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2...

Страница 12: ...lbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties...

Отзывы: