5
Branch
AWG (mm
2
) Wire Gauge Size at 90° C
Voltage/
Full
Circuit
Dist in Ft. (M) - Service to Motor
Model
Hertz
Load
Breaker
0-100
101-200
201-300
No.
(1 Phase)
Amps
Amp Rating
(0-30)
(31-60)
(61-90)
Single Speed Pumps:
5DJAFB-0001, -0101
230/50
5.6
15
14 (2)
14 (2)
12 (3)
5DJAEB-0001, -0101
230 / 50
5.5
15
14 (2)
10 (5.5)
8 (8.4)
5DJAGB-0003, -0103
230 / 50
8.7
15
14 (2)
14 (2)
12 (3)
DJAEA-0001
115 / 60
12
15
14 (2)
10 (5.5)
8 (8.4)
DJAEA-0007
115 / 60
12
15
14 (2)
10 (5.5)
8 (8.4)
DJAAGB-0001
230 / 60
11.1
15
14 (2)
14 (2)
12 (3)
DJAAGB-0005
230 / 60
12.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAAGB-0007
230 / 60
12
15
14 (2)
10 (5.5)
8 (8.4)
DJAAGB-0051, -0151
230 / 60
11.1
15
14 (2)
14 (2)
12 (3)
DJAAGB-0091
230 / 60
11.1
15
14 (2)
14 (2)
12 (3)
DJAEB-0001
230 / 60
6.2 / 1.7
15
14 (2)
14 (2)
14 (2)
DJAGB-0001
230 / 60
10.6
15
14 (2)
14 (2)
12 (3)
DJAGB-0021H, -0121H
230 / 60
10.6
15
14 (2)
14 (2)
12 (3)
DJAGB-0073, -0173, -3073, -3173
230 / 60
8.6
15
14 (2)
14 (2)
12 (3)
DJAGB-3173
230 / 60
8.6
15
14 (2)
14 (2)
12 (3)
DJAGB-0091, -0191
230 / 60
10.6
15
14 (2)
14 (2)
12 (3)
DJAGB-9051M
230 / 60
10.6
15
14 (2)
14 (2)
12 (3)
DJAGB-9055M, -9155M
230 / 60
9
15
14 (2)
14 (2)
12 (3)
DJAGB-9071M
230 / 60
10.6
15
14 (2)
14 (2)
12 (3)
DJAGB-9073, -9173
230 / 60
8.6
15
14 (2)
14 (2)
12 (3)
DJAHB-0007
230 / 60
12
15
14 (2)
14 (2)
12 (3)
DJAHB-0021H, -0121H
230 / 60
12 / 3.7
15
14 (2)
14 (2)
12 (3)
DJAHB-0041, -0141, -3141
230 / 60
12
15
14 (2)
14 (2)
12 (3)
DJAHB-0151
230 / 60
12
15
14 (2)
14 (2)
12 (3)
DJAHB-0055M, -0155M
230 / 60
12
15
14 (2)
14 (2)
12 (3)
DJAHB-0097
230 / 60
12
15
14 (2)
14 (2)
12 (3)
DJAFA-0001
115/60
16
25
12 (3)
8 (4)
6 (14)
DJAFC-0002
115/230 /60
16.4 / 8.2
25 / 15
12 (3)
8 (4)
6 (14)
DJAFC-0051M, -0151M
115/230 /60
16.4 / 8.2
25 / 15
12 (3)
8 (4)
6 (14)
DJAFC-0052, -0072, -0172
115/230 /60
16.4 / 8.2
25 / 15
12 (3)
8 (4)
6 (14)
DJAFC-0097
115/230 /60
16 / 8
25 / 15
12 (3)
8 (4)
6 (14)
DJAFC-3103D
115/230 /60
16.4 / 8.2
25 / 15
12 (3)
8 (4)
6 (14)
DJAGC-0007
115/230 /60
20 / 10
25 /15
10/14 (5.5/2)
8/14 (8.4/2)
6/12 (14/3)
Two-Speed Pumps:
5DJAYEB-0001, -0101
230/50
5.7 / 1.6
15
14 (2)
14 (2)
14 (2)
5DJAYFB-0097, 3007, -3097
230/50
8.2 / 2.6
15
14 (2)
14 (2)
12 (3)
DJAYEA-0001, -0002
115 /60
13 / 3.7
20
12 (3)
10 (5.5)
8 (8.4)
DJAYEA-0007
115 /60
11 / 2.9
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0052, -0152
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0061
115 /60
12 / 3.3
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0062, -0162, -3062
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0062A, -0162A
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0082, -0182
115 /60
11 / 2.9
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0112
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-0142A
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3022
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3052, -3152
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3052M, -3152M
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3097, -3197
115 /60
11 / 2.9
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3113
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-3142B
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYEA-9103
115 /60
10.4 / 3.6
15
14 (2)
10 (5.5)
8 (8.4)
DJAYFA-0001
115 /60
13 / 3.7
20
12 (3)
10 (5.5)
8 (8.4)
DJAYFA-0007
115 /60
13.8 / 3.8
20
12 (3)
10 (5.5)
8 (8.4)
TABLE IA – RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA
NOTE:
The second character of the model number suffix (the four characters following the dash) on pumps packed in bulk will be a “1”
(for example, – 3115). Identical pumps packed individually will have a suffix with a “0” replacing the “1” (for example – 3015).
When replacing a pump having a suffix “-X1XX”, order the same model with suffix “-X0XX”. When replacing a pump having a suffix “-X0XX”,
do not change the suffix.