background image

9

PUMP SERVICE

Pump should only be serviced by qualified personnel.

Be sure to prime pump (Pg. 7) before starting.

Before removing clamp or trap cover:

1. STOP PUMP before proceeding.
2. CLOSE GATE VALVES in suction and discharge pipes.
3. RELEASE ALL PRESSURE from pump and piping system.

4. NEVER tighten or loosen clamp while pump is operating!

To avoid dangerous or fatal electrical shock hazard, turn OFF power to

motor before working on pump or motor.

Aside from lubricating trap cover “O” Ring, no lubrication or regular mainte-
nance is needed beyond reasonable care and periodic cleaning of strainer
basket.
If shaft seal is worn or damaged, repair as follows:

Pump Disassembly/Removing Old Seal

Disconnect power to pump motor.

Be sure gate valves on suction and return piping are closed before start-

ing work.

Release all pressure by opening all vents before starting work.

1. Drain pump by removing drain plugs on bottom of pump body and trap

body.

2. Be sure there is no pressure in trap body; remove cover (unscrew by turn-

ing counterclockwise).

3. Remove clamp holding pump halves together. Motor and seal plate as-

sembly can now be pulled away from pump body.

4. Remove five screws and washers holding diffuser to seal plate. Remove

diffuser.

5. Remove motor canopy. Being careful not to touch capacitor terminals,

loosen capacitor clamp and move capacitor to one side.

6. Hold shaft with 7/16" open-end wrench on motor shaft flats.

7. Unscrew impeller from shaft (turn counterclockwise when facing it). 

NOTICE:  On models with impeller screw: Remove impeller screw  
(left hand thread - turn clockwise) and gasket before removing impeller.
Inspect gasket for damage, cracks, etc. Replace if damaged.

8. Pull rotating member of seal off of impeller sleeve; clean sleeve.

9. Remove four screws holding seal plate to motor.

10. Place seal plate face down on flat surface and tap out ceramic seat.

NOTICE: Do not force out heat sink insert (Key. No. 8, Pages 12-15). 
If insert has moved, pump will leak; see “Installing Heat Sink Insert,” 
Page 10.

11. Clean seal cavity in seal plate and clean motor shaft.

Hazardous voltage.
Can shock, burn,
or cause death.

Disconnect power
before working
on pump or motor.

Figure 4

Содержание DURA-GLAS II P4R Series

Страница 1: ...L P4RA6G 152L P4RA6GC 150 P4R6G3 153 2 1 2 P4RAA6G 153L 3 P4R6H3 154 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 F...

Страница 2: ...he Sta Rite P4R and P4RA Series II Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety In...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...CE Use Teflon tape or Plasto Joint Stik1 for making all threaded connec tions to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connec...

Страница 5: ...WIRING DATA Serv to Motor Dist in Ft M Motor Branch Fuse Max Load Voltage 0 100 101 200 201 300 HP Rating Amps Amps Hz Phase 0 30 M 30 60 M 60 90 M P4R Models 1 30 19 2 115 60 1 10 5 5 8 8 4 6 13 1 1...

Страница 6: ...onding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 fee...

Страница 7: ...a wrench only if necessary to remove lid Pump should prime now Priming time will depend on vertical length of suc tion lift and horizontal length of suction piping If pump does not prime make sure tha...

Страница 8: ...age plastic system components other anti freezes are highly toxic and may damage plas tic components in the system Drain all water from pump and piping when expecting freezing temperatures or when sto...

Страница 9: ...p body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together Motor and seal plate as sembly can now be pulled away from pump body 4 Remove five screws and washe...

Страница 10: ...ount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble motor and seal plate to volute be sure clamp is properly seated NOTICE Clamp knob can be located in any p...

Страница 11: ...h Clogged pipe trap impeller worn impeller 5 Make sure suction trap is not clogged if it is clean trap and strainer 6 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal...

Страница 12: ...U30 74SS Decal Suitable for outdoor use U27 635 Voltage Sticker 230 Volts U27 68 Voltage Sticker 115 230 Volts U27 153 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R...

Страница 13: ...Washer 2 U43 61SS 25 Base Screw 2 U30 918SS 26 Motor Pad 1 C35 43 27 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63...

Страница 14: ...U178 920P 23 Base w Motor Pad 1 C104 78P 24 Base Washer 2 U43 61SS 25 Base Screw 2 U30 918SS 26 Motor Pad 1 C35 43 27 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag C...

Страница 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Отзывы: