Pump Reassembly/Installing New Seal

1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outer

edge of “O” Ring with small amount of liquid detergent; press ceramic
seat into heat sink insert firmly and squarely with finger pressure (Fig. 5).

2. If ceramic seat will not locate properly, remove it, place face up on bench

and reclean cavity. Ceramic seat should now locate.

3. If seat still will not locate properly, place a cardboard washer over the

polished face and use a piece of 3/4" (19mm) standard pipe for pressing
purposes. NOTICE: Be sure not to scratch or mar polished surface or seal
will leak.

4. Remount seal plate on motor. Tighten bolts to 60-80 inch-lbs. 

(69-92 kg/cm) torque.

5. Apply a small amount of liquid detergent to inside diameter of rotating

half of seal.

6. Slide rotating seal member, polished face last, over impeller sleeve until

rubber drive ring hits shoulder (Figure 3).
NOTICE: Be sure not to nick or scratch polished seal face; seal will leak if
face is damaged.

7. Screw impeller onto shaft (clockwise); this will automatically locate seal in

seal plate.
NOTICE: On models with impeller screw: Install impeller gasket and lock
screw (left-hand thread - turn counterclockwise). Torque lock screw to
50-55 inch-lbs. (57.6-63 kg/cm).

8. Mount diffuser on seal plate; tighten screws to 10-14 inch-lbs. (11.2-16.1

kg/cm) torque.

9. Assemble motor and seal plate to volute; be sure clamp is properly

seated.
NOTICE: Clamp knob can be located in any position around volute; if it
is moved after assembly, tighten knob while tapping around clamp to as-
sist sealing. Do not move clamp while pump is full of water.

Hazardous pressure. Release all pressure from pump and

piping system before working on pump or attempting to adjust or re-
move clamp. Clamp may blow off of pump if adjusted under pressure.

10. Prime pump according to instructions on Page 7.

Installing Heat Sink Insert:

1. If the heat sink insert moves or shifts during seal removal, remove and re-

place with a new insert to prevent leakage.

Removal:

1. Remove two screws holding heat sink insert to seal plate.

2. Place seal plate face down on bench and use a short length of 1/2” pipe

to push insert out of seal plate.

3. Remove “O” Ring from insert cavity in seal plate and discard. 

NOTICE: Do not scratch “O” Ring seat in seal plate.

Installation:

1. Clean heat sink insert cavity in seal plate, including “O” Ring seat (step in

seal plate cavity - see Figure 7).
NOTICE: Do not scratch “O” Ring seat surface.

2. Lubricate new “O” Ring with petroleum jelly and insert into seat in seal

plate (Figure 8).

Figure 5: Press seal into heat sink in 

seal plate

Figure 6: Seal Plate/Heat Sink

sectional drawing

Figure 7: Clean O-Ring Seat

Figure 8: Install O-Ring in Seal Plate

Содержание DURA-GLAS II P4R Series

Страница 1: ...L P4RA6G 152L P4RA6GC 150 P4R6G3 153 2 1 2 P4RAA6G 153L 3 P4R6H3 154 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 F...

Страница 2: ...he Sta Rite P4R and P4RA Series II Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety In...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...CE Use Teflon tape or Plasto Joint Stik1 for making all threaded connec tions to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connec...

Страница 5: ...WIRING DATA Serv to Motor Dist in Ft M Motor Branch Fuse Max Load Voltage 0 100 101 200 201 300 HP Rating Amps Amps Hz Phase 0 30 M 30 60 M 60 90 M P4R Models 1 30 19 2 115 60 1 10 5 5 8 8 4 6 13 1 1...

Страница 6: ...onding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 fee...

Страница 7: ...a wrench only if necessary to remove lid Pump should prime now Priming time will depend on vertical length of suc tion lift and horizontal length of suction piping If pump does not prime make sure tha...

Страница 8: ...age plastic system components other anti freezes are highly toxic and may damage plas tic components in the system Drain all water from pump and piping when expecting freezing temperatures or when sto...

Страница 9: ...p body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together Motor and seal plate as sembly can now be pulled away from pump body 4 Remove five screws and washe...

Страница 10: ...ount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble motor and seal plate to volute be sure clamp is properly seated NOTICE Clamp knob can be located in any p...

Страница 11: ...h Clogged pipe trap impeller worn impeller 5 Make sure suction trap is not clogged if it is clean trap and strainer 6 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal...

Страница 12: ...U30 74SS Decal Suitable for outdoor use U27 635 Voltage Sticker 230 Volts U27 68 Voltage Sticker 115 230 Volts U27 153 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R...

Страница 13: ...Washer 2 U43 61SS 25 Base Screw 2 U30 918SS 26 Motor Pad 1 C35 43 27 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63...

Страница 14: ...U178 920P 23 Base w Motor Pad 1 C104 78P 24 Base Washer 2 U43 61SS 25 Base Screw 2 U30 918SS 26 Motor Pad 1 C35 43 27 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag C...

Страница 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Отзывы: