background image

11

1

5

6

11

12

13

See Box A

See Box A

16

18

17

19

15

14

10

10A

7

8

9

3

4

2

2A

21

22

23

24

20

10B

4285 1102

Key

Part

Part

No.

Description

Qty.

No.

1

Motor 

1

Chart at Right

2

#10-32 x 1/2” Screw 

1

U30-692SS

3

Bonding Lug

1

U17-568

4

Water Slinger

1

17351-0009

5

Seal Plate

1

C103-194P

6

O-Ring

1

U9-228A

7

Shaft Seal

1

37400-0027S

8

Clamp

1

C19-37A

9

Clamp Knob

1

WC36-22

10

Impeller

1

Chart at Right

10A

Impeller O-Ring*

1

35505-1426

10B

Impeller Screw*

1

37337-6081

11

Diffuser

1

C1-271P

12

Diffuser O-Ring 

1

U9-374

13

#8 Lock Washer

5

U43-21SS

14

#8 - 32 x 1-1/8” Screw 

5

U30-922SS

15

Tank Body (BSP Threads)

1

17307-0110W

16

Trap Cover**

1

17307-0111S

17

Trap O-Ring

1

35505-1440

18

Basket

1

C8-58P

19

1/4” NPT Drain Plug 

2

U178-920P

20

Base Washer

2

U43-41SS

21

Base Screw

2

U30-918SS

22

Base w/Motor Pad

1

C104-78P

23

Motor Pad

1

C35-43

24

3/8-16 x 1” Hex Head Screw 

4

U30-74SS

• Motor 

Nameplate

1  32155-7117

• Tag, 

“CAUTION”

61002-0002

Tag, “CAUTION, WARNING (Bonding)

C63-12

Nameplate

U33-174

5P6R SERIES

50 Hz. MAX-E-PRO POOL PUMP

3/4 and 1 HP

• Not illustrated.     * Three phase only.
** Includes Trap Cover, Trap Ring and Trap Cover O-Ring.

REPAIR PARTS LIST

Motor No.

Impeller No.

Model No.

HP

(Key No. 1)

(Key No. 10)

115/230 Volt - 1 Phase

5P6R6D-209

3/4

J218-574A

C105-238PF

5P6R6E-210

1

J218-575A

C105-238PG

220-240/380-415 Volt - 3 Phase

5P6R6D3-209

3/4

J218-815A

C105-238PFA

5P6R6E3-210

1

J218-816A

C105-238PGA

Parts are common to all models listed except as noted;
Key Nos. 1, Motor; and 10, Impeller are listed below.

For quick disconnect pipe connections,
purchase separately:
Pkg. 188 2" Slip 1/2 Union Kit or
Pkg. 189 2" NPT 1/2 Union Kit.
Includes 2 each:
U11-200P Union Collar
U9-362 O-Ring
U11-196P 2" Slip adapter or
U11-199P 2" NPT adapter.

Box A

Содержание 5P6R Series

Страница 1: ...R6F 211 5P6R6F3 211 2 5P6R6G 212 5P6R6G3 212 3 5P6R6H 213 5P6R6H3 213 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life Sta Rite Industries Export Sales Marketing Group 293 Wright Street Delavan WI 53115 U S A TELEPHONE 262 728 5551 TELEFAX 262 728 4461 CABLE STAREX TELEX ITT 4970245 Printed in U S A S764...

Страница 2: ... professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or spa installation 3 Install pump with at least 2 hydraulically balanced main drains equipped with correctly installed screw fastened anti entrapment certified covers See Page 4 4 Trapped air in system can cause explosion BE SURE all air is out of system before o...

Страница 3: ...or To avoid burns when handling the motor let it cool for 20 minutes before trying to work on it Teflon Taping Instructions Use only new or clean PVC pipe fittings Wrap male pipe threads with one to two layers of Teflon tape Cover entire threaded portion of pipe Do not overtighten or tighten past thread stop in pump port If leaks occur remove pipe clean off old tape rewrap with one to two addition...

Страница 4: ... that is there must be at least two main drains connected to the pump whenever it is running See Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shutoff both main drains from the pump see Figure 2 More than one pump can be connected to a single suc tion line as long as the requirements above are met Water Velocity T...

Страница 5: ...motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 feet 1 5 m of the inside walls of swimming pool spa or hot tub Wiring Pump must be permanently connected to circuit Match wire and circuit breaker sizes to Table I Page 6 If other lights or appliances are also on the same circuit be sure to add their amp loads t...

Страница 6: ...Figure 5A Voltage Change Plug Set for 230 Volts TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to Motor Dist Meters Motor Branch Fuse Max Load Voltage HP Rating Amps Amps Hz Phase 0 30 M 31 61 M 62 91 M 3 4 20 12 2 115 50 1 3 0 5 5 8 4 1 20 15 4 115 50 1 3 0 8 4 14 0 1 1 2 30 19 4 115 50 1 5 5 8 4 14 0 3 4 15 6 1 230 50 1 2 0 2 0 2 0 1 15 7 7 230 50 1 2 0 2 0 2 0 1 1 2 15 9 7 230 50 1 2 0 2 0 3 0...

Страница 7: ... original equipment O Ring contains a permanent internal lubricant NOTICE If you replace the O Ring with a non internally lubricated O Ring you may need to apply a silicone based lubricant Clean and inspect O Ring reinstall on trap Replace trap cover and handle ring on trap turn handle ring clockwise to tighten cover NOTICE Tighten trap cover handle ring by hand only no wrenches Pump should prime ...

Страница 8: ...ion problems do not cover pump with plastic For outdoor unprotected installations 1 Gravity drain system as far as possible 2 Protect areas which retain water with non toxic propy lene glycol antifreeze RV antifreeze 3 Enclose entire system in a weatherproof enclosure 4 To avoid condensation corrosion damage allow venti lation do not wrap system in plastic 5 Use a 40 propylene glycol 60 water solu...

Страница 9: ...mic seat into seal plate firmly and squarely with finger pressure Figure 7 2 If ceramic seat will not lo cate properly remove it place face up on bench and reclean cavity Ceramic seat should now locate 3 If seat still will not locate properly place a cardboard washer over the polished face and use a piece of 3 4 19mm standard pipe for pressing purposes NOTICE Be sure not to scratch or mar polished...

Страница 10: ...ogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 9 for reassembly 7 Impeller and diffuser may be worn If so order re placement parts from Repair Parts List Pages 11 14 8 Pump may be trying to push too high a column of water If so a higher head pump is needed Electrical 9 Pump may be running too slowly...

Страница 11: ...Base Screw 2 U30 918SS 22 Base w Motor Pad 1 C104 78P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Hex Head Screw 4 U30 74SS Motor Nameplate 1 32155 7117 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 5P6R SERIES 50 Hz MAX E PRO POOL PUMP 3 4 and 1 HP Not illustrated Three phase only Includes Trap Cover Trap Ring and Trap Cover O Ring REPAIR PARTS LIST Motor No Impeller No Mode...

Страница 12: ...37A 9 Clamp Knob 1 WC36 22 10 Impeller 1 Chart at Right 10A Impeller O Ring 1 35505 1426 10B Impeller Screw 1 37337 6080 11 Diffuser 1 C1 271P 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 8 32 x 7 8 Screw 5 U30 542SS 15 Tank Body BSP Threads 1 17307 0110W 16 Trap Cover 1 17307 0111S 17 Trap O Ring 1 35505 1440 18 Basket 1 C8 58P 19 1 4 NPT Drain Plug 2 U178 920P 20 Base Washer 2 U43 ...

Страница 13: ... 12 Diffuser O Ring 1 U9 374 13 8 Lock Washer 5 U43 21SS 14 8 32 x 1 1 8 Screw 5 U30 922SS 15 Tank Body BSP Threads 1 17307 0110W 16 Trap Cover 1 17407 0111S 17 Trap O Ring 1 35505 1440 18 Basket 1 C8 58P 19 1 4 NPT Drain Plug 2 U178 920P 20 Base Washer 2 U43 41SS 21 Base Screw 2 U30 918SS 22 Base w Motor Pad 1 C104 79P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Socket Head Screw 4 U30 99SS Motor Namepla...

Страница 14: ...r U18 1098 U18 1098 U18 1098 U18 1529 U18 1529 5 Governor U18 253 U18 253 U18 253 U18 253 U18 253 6 Overload Protector U18 983 U18 1137 U18 1139 599 13096 599 13698 7 Canopy U18 1235 U18 1235 U18 1235 U18 1235 U18 1288 U18 1235 U18 1235 U18 1235 U18 1235 U18 1288 8 Terminal Board U18 1180 U18 1180 U18 1180 U18 1457 U18 1457 9 End Bell Switch End U18 1289 U18 1289 U18 1289 U18 1282 U18 1293 U18 128...

Страница 15: ...15 ...

Страница 16: ...16 ...

Отзывы: