background image

Retain Warranty Certificate (upper portion) in a safe and convenient location for your records.

DETACH HERE: Fill out bottom portion completely and mail within 10 days of purchase/installation to:

▼   

Sta-Rite, Attn: Warranty Dept., 293 Wright St., Delavan, WI 53115 

Pumps, filters, skimmers, underwater lights (except bulbs),
accessories and fittings manufactured by Sta-Rite are war-
ranted to be free of defects in material and workmanship
for one (1) year from date of installation.

Product specific warranties: 

Year from date 

of installation

HRPB, DEPB and System 3

– Tanks  . . . . . . . . . .10 years

Internal filter components and valves   . . . . . . . . 1 year

Max-E-Therm

– Pool/Spa Heaters   . . . . . . . . . . . . 2 years

Heater Enclosure only (Upper RH & LH; 
lower enclosure; and control board enclosure)…10 years

Automatic Pool Cleaners including Hose

 . . . . . . 2 years 

Cristal-Flo filters

– Tanks  . . . . . . . . . .10 years pro-rated* 

Valve and internal components.  . . . . . . . . . . . . . 1 year

Posi-Flo II

– Tanks . . . . . . . . . . . . . . . . . . . . . . . .10 years 

Elements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

PRC Cartridge

– 

Filter Tanks  . . . . . . . .5 years pro-rated (1st 2 years full) 
Elements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

System 3 Above Ground Systems 

– Tanks  . . . . . .10 years 

Pumps / Platform and Internals  . . . . . . . . . . . . . 1 year

Pumps  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1 year

When equipped with A.O. Smith 
2-compartment motors (Does not include
pumps sold as part of a systems package)  . . . . . 2 years

Traps / In-Line Strainers

 . . . . . . . . . . . . . . . . . . . 1 year 

Vertical Commercial Filter

– Tanks  . . . . . . . . . .10 years 

Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

Horizontal Commercial Filter

Tanks  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 years
(Years 6-9, Prorated declining 20%/year, Yr. 10 - 10%)
Internals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year

* Full warranty coverage is in effect for one year after instal-
lation. The pro-rated warranty covers the 

tank only

during

the 2nd through 10th year after installation. The amount
covered decreases by 10% each year. (ie., 2nd year 90% cov-
ered, 3rd year 80% covered, etc.).

The foregoing warranties relate to the original consumer
purchaser (“Purchaser”) only. Sta-Rite shall have the option
to repair or replace the defective product, at its sole discr-
tion. Purchasers must pay all labor and shipping charges
necessary to replace the product covered by this warranty.
Requests for warranty service must be made through the
installing dealer. This warranty shall not apply to any prod-
uct that has been subject to negligence, misapplication,
improper installation or maintenance, or other circum-
stances which are not in Sta-Rite’s direct control.

This warranty sets forth Sta-Rite’s sole obligation and
Purchaser’s exclusive remedy for defective products.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUEN-
TIAL, INCIDENTAL OR CONTINGENT DAMAGES WHATSO-
EVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN
LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND
BEYOND THE DURATION OF THE APPLICABLE EXPRESS
WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of inci-
dental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclu-
sion may not apply to you. This warranty gives you specific
legal rights and you may also have other rights which vary
from state to state.

Supersedes all previous publications.

Sta-Rite Industries
293 Wright St., Delavan, WI 53115

Warranty Registration Card

Name 

Address 

City State 

Zip 

Purchase Date 

Product Purchased 

New installation 

Replacement

Type of Pool

Inground 

Vinyl

Fiberglass

Gunite

Size of Pool 

Years pool has been in service    

less than 1    

1-3    

3-5    

5-10

Purchased from: 

Company name

Address 

City State 

Zip 

Please send me more information on these 

other products from Sta-Rite.

Pumps    

Filters   

Automatic Pool Cleaners

Maintenance Equipment    

Test Strips

Heaters

S4877PS (Rev. 5/15/00)

STA-RITE LIMITED WARRANTY

Содержание 1/2 HP

Страница 1: ...Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2004 Sta Rite Industries Printed in U S A S44 Rev 4 5 04 This manual should be furnished to the end user of this pump its use will reduce service calls and chance of injury and will lengthen pump life ...

Страница 2: ... CAREFULLY The Sta Rite PLB Series Booster pump Is designed for use with automatic swimming pool cleaning systems Is an excellent performer durable reliable Table of Contents Safety Instructions 3 Installation 4 5 Electrical 6 Operation 7 Storage Winterizing 7 Pump Service 8 9 Repair Parts List 10 Troubleshooting Guide 11 Warranty 12 ...

Страница 3: ...ty checks Check all clamps bolts lids and system accessories before testing Release all air in system before testing Tighten Sta Rite trap lids to 30 ft lbs 4 1 kg m torque for testing Water pressure for test must be less than 25 PSI 7 5 kg cm2 Water Temperature for test must be less than 100o F 38o C Limit test to 24 hours After test visually check system to be sure it is ready for operation Remo...

Страница 4: ...nstall pump and wiring Pump mount must Be solid Level Rigid Vibration free To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet to be as close to pool return line as possible Allow use of short direct suction pipe from tee on return line See Fig 1 Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be protected from exce...

Страница 5: ...discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid airlocking slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flood ed suction systems must have gate valves in suction and discharge pipes Fittings...

Страница 6: ...swimming pool spa or hot tub Wiring See Figure 3B Pump must be permanently connected to circuit Table I Page 6 gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit breaker sizes If unsure how to do this or if this is confusing consult a licensed ele...

Страница 7: ...oblems do not cover pump with plastic For outdoor unprotected installations 1 Enclose entire system in a weatherproof enclosure 2 To avoid condensation corrosion damage allow ventilation do not wrap system in plastic 3 Use a 40 propylene glycol 60 water solution to protect pump to 50 F Draining Pump 1 Pump down water level below all inlets to the pool To avoid dangerous or fatal electrical shock h...

Страница 8: ...user Figure 5 5 If impeller must be replaced loosen two machine screws and remove motor canopy see Figure 6 6 Capacitor voltage may be hazardous To discharge capaci tor hold insulated handle screwdriver BY THE HANDLE and short capaci tor terminals together see Figure 6 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a qualified electrician 7 Unscrew capacitor clamp ...

Страница 9: ...right side up 8 Apply liquid soap sparingly one drop is sufficient to inside diameter of rotating seal member 9 Slide rotating seal member carbon face first onto shaft until rubber drive ring hits shaft shoulder NOTICE Be sure not to nick or scratch carbon face of seal when pass ing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 10 ...

Страница 10: ...al 1 17351 0102S 7 Impeller 1 J105 8PACN 8 Diffuser 1 J1 40P 9 Screw 8 32 x 7 8 Lg 5 U30 542SS 10 O Ring Diffuser 1 U9 199 11 Clamp Tank Body 1 C19 54SS 12 Reducer Bushing 1 U78 118PT 13 Tank Body Front Half 1 L76 37P 14 Pipe Plug 1 8 1 WC78 41T 15 Bushing 1 L23 4P1 15A Gasket 1 L20 40 16 Reducer Bushing 1 1 4 x 3 4 1 U78 123PT 17 Pipe Plug 1 1 U78 830PT 18 Pipe Plug 1 4 2 WC78 40T 19 Base 1 C4 42...

Страница 11: ...eal Page 9 for reassembly 2 Impeller and diffuser may be worn If so order replacement parts from Repair Parts List Page 10 Electrical 1 Pump may be running too slowly check voltage at motor terminals and at meter while pump is running If low see wiring instructions or consult power company Check for loose connections 2 Pump may be too hot A Check line voltage if less than 90 or more than 110 of ra...

Страница 12: ...er purchaser Purchaser only Sta Rite shall have the option to repair or replace the defective product at its sole discr tion Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty Requests for warranty service must be made through the installing dealer This warranty shall not apply to any prod uct that has been subject to negligence misapplicat...