Hardware description
UM1975
12/20
DocID028608 Rev 1
2.3
Current measurement
To monitor the power consumption of the onboard SPWF01SA module, remove the R3
(0
Ω resistor) and, using jumper JP1 contacts as connectors, insert an ammeter probe
between pins 1 and 2 of the connector and measure current absorption.
Since the power consumption of the SPWF01SA module is usually very low, accurate
instrumentation able to take measurements in the order of a few µA may be required.
2.4
X-NUCLEO-IDW01M1 component placement details
The following figure shows component placement on the X-NUCLEO-IDW01M1 board
Figure 3: X-NUCLEO-IDW01M1 component placement details