Flat ribbons
UM2448
28/42
UM2448 Rev 5
9 Flat
ribbons
The STLINK-V3SET provides three flat cables allowing the connection from the STDC14
output to:
•
STDC14 connector (1.27 mm pitch) on target application: pinout detailed in
.
Reference Samtec FFSD-07-D-05.90-01-N-R.
•
ARM10-compatible connector (1.27 mm pitch) on target application: pinout detailed in
. Reference Samtec ASP-203799-02.
•
ARM20-compatible connector (1.27 mm pitch) on target application: pinout detailed in
. Reference Samtec ASP-203800-02.
Table 15. ARM10-compatible connector pinout (target side)
Pin No.
Description
Pin No.
Description
1
T_VCC
(1)
1. Input for STLINK-V3SET.
2
T_JTMS/T_SWDIO
3
GND
4
T_JCLK/T_SWCLK
5
GND
6
T_JTDO/T_SWO
(2)
2. SWO is optional, required only for Serial Wire Viewer (SWV) trace.
7
T_JRCLK
(3)
/NC
(4)
3. Optional loopback of T_JCLK on the target side, required if loopback removed on the STLINK-V3SET side.
4. NC means not required for the SWD connection.
8
T_JTDI/NC
9
GNDDetect
(5)
5. Tied to GND by STLINK-V3SET firmware; may be used by the target for detection of the tool.
10
T_NRST
Table 16. ARM20-compatible connector pinout (target side)
Pin No.
Description
Pin No.
Description
1
T_VCC
(1)
1. Input for STLINK-V3SET.
2
T_JTMS/T_SWDIO
3
GND
4
T_JCLK/T_SWCLK
5
GND
6
T_JTDO/T_SWO
(2)
2. SWO is optional, required only for Serial Wire Viewer (SWV) trace.
7
T_JRCLK
(3)
/NC
(4)
3. Optional loopback of T_JCLK on the target side, required if loopback removed on the STLINK-V3SET side.
4. NC means not required for the SWD connection.
8
T_JTDI/NC
9
GNDDetect
(5)
5. Tied to GND by STLINK-V3SET firmware; may be used by the target for detection of the tool.
10
T_NRST
11
NC
12
NC
13
NC
14
NC
15
NC
16
NC
17
NC
18
NC
19
NC
20
NC