![ST STEVAL-ISB044V1 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/st/steval-isb044v1/steval-isb044v1_user-manual_1356002031.webp)
UM2301
GUI
and evaluation procedure
DocID031141 Rev 1
31/57
Level 1: more critical parameters to be modified with caution. You must click the
Unlock param
button before modifying it, with caution, as it can lead to system
malfunction or trigger unexpected behavior incompatible with Qi standard.
Figure 36: STSW-STWBCGUI: Parameters window
Parameters can be modified and their effect can be tested immediately by clicking
Push to
target
; modified parameters lose their highlighted background.
Figure 37: STSW-STWBCGUI: modified parameters
The GUI embeds the STSW-STWBCFWDT downloader interface (which uses UART
connection) and includes tools to generate binary files with adjusted parameters and to
build new firmware packages incorporating these files.