![ST ST10-C Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/st/st10-c/st10-c_hardware-manual_1355667033.webp)
33
ST5/10-Si,-Q,-C, IP Hardware manual
920-0004 Rev. F
6/10/14
Connecting a Potentiometer to Analog Input 1
Analog Inputs
The ST drives feature two analog inputs. Each input can accept
a signal range of 0 to 5 VDC, ±5 VDC, 0 to 10 VDC or ±10 VDC.
The drive can be configured to operate at a speed or position
that is proportional to the analog signal.
A shielded cable is recommended for electrically noisy
environments.
Use the
ST Configurator
software to set the signal range, offset,
deadband and filter frequency.
inside drive
AIN1
AIN2
GND
1
2
13
DB-25 Connector
Signal
Conditioning
Signal
Conditioning
1-10k
W
pot
cw
ccw
DRIVE
GND
AIN
+5V OUT
18
1
13
AIN2
2