Page 2 

Hastings Installations Manual 

 

INSTALLATION CHECK LIST 

BEFORE INSTALLATION

 

Thoroughly read and understand this manual. SAVE THIS MANUAL. 
 
Check with local authorities and obtain needed permits 
 
3. It is strongly recommended that the stove receive a Dealer’s 

“Pre-delivery Check”

 prior to 

 installation. 
 
4. We recommend installation by a qualified professional. 
 

BEFORE STARTING THE STOVE FOR THE FIRST TIME 
 

1. Outside combustion air may be recommended for certain installations (negative pressure). Use 
only  approved  parts.  Outside  air  kit  #  100354  is  available  or  any  comparable  components  as 
listed on page 14. 
 
2. All joints of PL vent and single wall stainless steel pipe should be fastened by at least 3 screws 
and  correctly  installed.  (Follow  vent  manufacturer’s  instructions).  Seal  all  joints  with  high 
temperature silicone to create an airtight seal.  
 
3. Any “plated” areas should be cleaned thoroughly with a glass cleaner such as Windex® and a 
soft cloth just before lighting the first fire. This will remove fingerprints and oils that may cause 
a permanent stain or mark on the gold plating the first time it is heated. Never use an abrasive 
cleaner or material on any plated or painted surfaces. Never clean the plated surfaces when stove 
is hot. 
 
4. WARNING: The high temperature paint on this stove may take several hours of burning at a 
high  fuel  setting  to  cure  fully.  During  this  time,  an  odor  that  is  not  harmful  may  be  evident. 
When odors are present, the area around the stove should be well ventilated. 

 

5. Caution: The high temperature paint can be easily scratched prior to burning the stove. 

Содержание Hastings

Страница 1: ...ng Termination Requirements 12 13 Combustion Air 15 Electrical Connections 16 Floor Protection 17 Clearances to Combustible Materials 18 Mobile Home Installation 20 Thermostat Installation and Operation 22 Contact local building or fire officials about restrictions and installation inspection requirements in your area Please read this entire manual before installation and use of this pellet fuel b...

Страница 2: ...Y LOCAL INSTALLATION RESTRICTIONS AND INSPECTION REQUIREMENTS DEFINITION OF STOVE The word stove as used in this manual is interpreted to mean a pellet burning freestanding stove insert or zero clearance fireplace unless otherwise noted SAFETY TESTING The stove has been independently tested and listed by Warnock Hersey Laboratories in accordance with the proposed ASTM Standards and the applicable ...

Страница 3: ...east 3 screws and correctly installed Follow vent manufacturer s instructions Seal all joints with high temperature silicone to create an airtight seal 3 Any plated areas should be cleaned thoroughly with a glass cleaner such as Windex and a soft cloth just before lighting the first fire This will remove fingerprints and oils that may cause a permanent stain or mark on the gold plating the first t...

Страница 4: ...astings is approved for CONVENTIONAL and MOBILE HOME installations as a FREESTANDING stove The stove may also be installed on the Hearth in front of a fireplace and vented through the chimney of the fireplace WARNING The stove must not be installed in a sleeping room ...

Страница 5: ...aVent Energy Vent LTD James A Ryder and Selkirk Metalbestos and is carried by many local pellet stove dealers In this manual approved venting will be referred to a PL vent or Single wall vent All single wall vent adaptors must be stainless steel NOTE TYPE B GAS VENT MUST NOT BE USED IN ANY PELLET STOVE INSTALLATION Examples of venting system components follow High temperature ceramic roping reduce...

Страница 6: ...PICAL PL VENT COMPONENTS RAIN CAP VERTICAL OR WALL THIMBLE CHIMNEY SUPPORT BRACKET HORIZONTAL ADAPTER ADJUSTABLE LENGTH SINGLE TEE SINGLE REDUCTION DOUBLE TEE PIPE w TEE CAP TEE w TEE CAP w TEE CAP PIPE ADAPTER INCREASER 450 ELBOW 900 ELBOW ...

Страница 7: ... CLEARANCES TO COMBUSTIBLES AS REQUIRED STRICTLY OBSERVE THE PL VENT MANUFACTURER S SAFETY SPECIFICATIONS QUANTITY OF MATERIALS 1 Installing the vent system with a minimum of three feet 3 of vertical rise above the stove exhaust port will provide some Natural Draft FAILURE TO PROVIDE THE NATURAL DRAFT THAT RESULTS FROM A VERTICAL RISE MAY RESULT IN SMOKE BEING RELEASED INTO THE HOUSE WHEN ELECTRIC...

Страница 8: ...stallation over 12 is NOT RECOMMENDED D Less than 15 vertical 3 Acceptable E Over 15 vertical 4 Required F Above 4000 elevation 3 or 4 Acceptable Note Four 4 inch vent may be used in all installations If in doubt use 4 vent Figure 1 REAR SIDE VIEW A Width of stove B Height of stove C Center of intake tube from floor D Center of stove to center of intake tube E Center of stove to center of exhaust ...

Страница 9: ...ee elbow I PL Vent Fire Stop B Thimble J Roof Flashing C PL Vent Section K Storm Collar D Stove Exhaust Pipe L Rain Cap E Air Intake Damper M Outside Air Pipe F Air Vent Damper N PL Vent Section G 90 degree elbow O Wall Band H 45 degree elbow P Outside Air Inlet Cover 1 PL vent may be installed directly through a combustible wall ceiling or roof according to PL vent manufacturer s instructions See...

Страница 10: ...hen terminating the exhaust system under the house eaves Figure 4 the end of the vent pipe system must be at least twelve inches 12 from the wall and 24 below the eave a 90 degree G and a 45 degree elbow may be used H 2 When extending through the roof Figure 5 install a PL vent fire stop I in the ceiling or in the eaves if the eaves are boxed in Install roof flashing J and a storm collar K Extend ...

Страница 11: ...ap that reduces the outlet of the chimney to the size of the liner is required Extend the exhaust vent above the chimney chase cap and finish it off with a rain cap A single wall liner may need to be insulated to maintain adequate exhaust temperatures in the vent system Note Outside Chimneys frequently are difficult to keep warm if in doubt insulate the liner Figure 6 Figure 7 Venting into Masonry...

Страница 12: ...nal Figure 8 Venting to the Top of Chimney When installing as a hearth mount stove into a fireplace the unit must either be relined terminating above the chimney chase top or positively connected to the existing chimney system using a block off plate D An approved flex liner of PL vent must be used A chimney system with known drafting problems may require a liner which may also need to be insulate...

Страница 13: ...orts garage attic crawl space etc or any location that can build up a concentration of fumes 3 Vent surfaces can get hot enough to cause burns if touched by children Non combustible shielding or guards may be required The type of installation must first be considered before determining the exact location of the venting termination in relation ship to doors window cavities or air vents See figures ...

Страница 14: ...rom the outside atmosphere and all flue gases are discharged to the outside atmosphere Special Venting Arrangements are listed in NFPA 211 31 10 7 1 2 The Vent Terminal of a Direct Vent Appliance with an input of 10000 BTU Hr or less shall be located at least 6 from any opening into a building and such an appliance with an input of over 10000 BTU Hr but not over 50000 BTU Hr shall not be located l...

Страница 15: ...oint 3 915mm FROM a gas meter regulator assembly 2 610 mm FROM any adjacent combustibles such as Adjacent buildings fences protruding parts of the structure roof eaves or overhangs plants shrubs etc Note Certain local code restrictions may apply Check with Local Officials first before installing FIGURE 10 VENTING TERMINATION CLEARANCE REQUIREMENTS SIDE VIEW All dimensions show MINIMUM distances ...

Страница 16: ...above the maximum snow line and below the exhaust vent outlet 2 Outside air may be drawn from a semi enclosed attic or crawl space or any semi enclosed space Take care not to draw cold air past water pipes that may freeze 3 Increase the outside air pipe diameter to 3 for runs over ten 10 feet and elevation over 4 000 feet Note Long runs should be avoided 4 Terminate the outside air pipe below the ...

Страница 17: ...ately 3 amps 5 amps with igniter running 2 The power cord must be carefully routed to avoid contact with any hot or sharp exterior surface areas of the stove Figure 11B Any stove installed in a mobile home must be electrically grounded to the steel chassis of the home and bolted to the floor in Model compliance with and according to building code requirements 3 In Canada the electrical installatio...

Страница 18: ...d on a non combustible protective pad Hearth models may be placed directly on the noncombustible hearth of a fireplace The Hearth must extend a minimum of 6 152 mm in Front of Unit and beyond each side of the Fuel Loading and Ash Removal Opening s Figure 12 Floor protection Top View ...

Страница 19: ... B Back of stove 4 13 Corner of stove 4 13 Vent pipe 3 15 Stove to mantel 12 15 Floor protection Front from faceplate 6 12 Floor protection Sides back of stove 0 16A Alcove Vertical to Combustibles 16 16B Alcove Sides 4 16A 16B Alcove Back 4 Figure 13 Top View Figure 14 Top View Clearances corners of stove Clearances Sides and Back ...

Страница 20: ...Installation Top View Figure 16B Although 4 is the minimum clearance to the sides of the stove this is not recommended due to the need for access into the inside of the stove for the maintenance as spelled out in the Operations Manual Please read the section covering Daily Periodic and Yearly Maintenance in the Operations Manual ...

Страница 21: ...dition to all previously detailed requirements mobile home installations must observe the following Figure 17 1 WARNING DO NOT INSTALL IN A SLEEPING ROOM 2 WARNING COMBUSTION AIR MUST COME FROM THE OUTSIDE OF THE MOBILE HOME FAILURE TO DO SO MAY CREATE NEGATIVE PRESSURE WITHIN THE MOBILE HOME AND COULD DISRUPT PROPER VENTING AND OPERATION OF THE PELLET STOVE 3 CAUTION THE STRUCTURAL INTEGRITY OF T...

Страница 22: ...t location where PL vent exits the structure 7 Check any other local building codes or other codes that may apply 8 Do no use components other than those specified for use with this unit Refer to pages 4 5 6 and 7 9 Floor protection requirement must be followed precisely 10 PL Vent must be used for exhaust venting Single wall vent is not allowed Follow PL Vent manufacturer s installation direction...

Страница 23: ...n the T Stat Mode and the SmartStat Mode We recommend using the Fully Automatic SmartStat Mode 1 Once you have successfully lit your stove set the thermostat to your desired heating needs 2 Set the HEAT ADJUST selector to a position that will effectively create a rise in room temperature above your thermostat setting The recommended heat adjust settings while using a thermostat are any position be...

Страница 24: ...Page 23 Hastings Installations Manual Notes Serial Number Date of Purchase Dealer Information Even Temp Inc P O Box 127 Waco NE 68460 EMAIL support stcroixstoves com WEB ADDRESS www stcroixstoves com ...

Отзывы: