MGW/920 Smart Metering Gateway- First Steps
8
M a n u a l R e v i s i o n 1 . 1
3.2
Connecting Power Supply and Power-up the MGW/920
Connect the 12 VDC power supply with the 5.5 mm x 2.5 mm barrel plug to the
MGW/920.
Fig. 5:
Power supply for the MGW/920
CAUTION: Providing the MGW/920 with a voltage higher than the regular 12 VDC
±10 % could resolve in damaged board components!
Please pay attention to the polarity of the power connector: the + pole is in the center!
Fig. 6:
Polarity of the power connector