3
English
Installation
Application
The bollard lamp PL 001 and
PL 002, pedestal made of sectional
extruded aluminium for free-
standing installation. As a design
element, in gardens, on steps,
paths, drives or walkways.
Important notes
!
•
The bollard lamp can
only
be
mounted on a firm basis such as a
concrete foundation complying to
“B 25” or compression resistant
natural stone.
Foundation size 50 x 50 x 70 cm or
a floor plate of 1 m
2
and 15 cm in
thickness.
•
Also suitable for concreting in
when used in conjunction with
ground accessory ZE/KSF 611-0.
•
Electrical appliances may only be
installed, mounted and serviced by
suitably qualified electrical
engineers.
•
Electrical connections in the low-
voltage range (up to 1000 V) must
be made in accordance with
VDE 0100/DIN 57100.
•
The bollard lamp may only be
connected using the pre-installed
cable (H05RN-F 1mm
2
).
•
The device may only be opened
when not live.
•
In order to prevent injury, the
device must be reliably secured to
the ground as indicated in the
installation instructions.
•
Light sources
with E27 socket
and integrated ballast, type used
TC-DSE, e.g. Osram Dulux EL (DEL
LL 20)
Scope of delivery of the PL 001
1
a
Pedestal complete with floor
flange
b
Front panel
One mounting accessory set
comprising:
c
3 x screw covers
d
3 x hexagonal screws
M10 x 80 DIN 24017
e
3 x flat washers DIN 125
f
3 x heavy-duty floor plug
SLM 10 N
g
White translucent glazing panel
with all-round seal for scattered
light.
h
Prefitted lampholder
i
Prefitted IP 54 splitting box,
j
Allen key size 2.5
Scope of delivery of the PL 002
2
a
Pedestal complete with floor
flange
b
Front panel
One mounting accessory set
comprising:
c
3 x screw covers
d
3 x hexagonal screws
M10 x 80 DIN 24017
e
3 x flat washers DIN 125
f
3 x heavy-duty floor plug
SLM 10 N
g
Lamp cover for directed
light
h
Prefitted lampholder
i
Prefitted IP 54 splitting box,
j
Allen key size 2.5
Mounting
3
Remove the glazing panel / lamp
cover
Using the provided Allen key, back
out the concealed screw until the
glazing panel/light cover can be
tilted and removed
Remember to replace the
!
Allen screw afterwards
4
Remove the front panel
5
(not illustrated)
Mark in the fastening holes of the
pedestal
6
(not illustrated)
Drill the fastening holes (12 mm,
60 mm deep) and set the heavy-
duty floor plugs
7
(not illustrated)
Guide the installation cable through
the floor plate and fasten the
bollard lamp. Position the screw
cover.
8
(not illustrated)
Strip the connecting cable over a
suitable length and correctly carry
out the electrical connection.
After installation, the junction
!
box must be securely mounted
in the pedestal and sealed shut.
9
(not illustrated).
Insert the light source.
10
Insert the front panel
11
Insert the glazing panel / lamp
cover.
The recess must be
!
at the bottom.
Servicing
Exchanging the light source
12
Remove the glazing panel/lamp
cover and change the light source
13
Replace the glazing panel/lamp
cover
Specifications
•
Operating voltage 220-240 V AC
•
Light source max. 23 W
•
Prefitted splitting box IP 54
•
Dimensions:
W x H x D 211 x 844 x 230 mm
Содержание PL 001