SSS Siedle DoorCom IP Multi DCIP 740 Series Скачать руководство пользователя страница 3

3

Find out about the necessary safety 
measures and system requirements 
before starting installation and com‑
missioning of the DoorCom IP.

System requirements for configu

-

ration software DCIP CO 600‑0

• PC with Intel Pentium III from 
1 GHz or comparable processor
• at least 512 MB RAM
• min. 25  MB hard disk memory
• USB port or serial port depending 
on which PRI 602‑... is being used
• CD‑ROM drive for installation 
• VGA graphics card with at least 
1024 x 768 pixel
• Operating system Windows 2000/
XP/Vista 32 Bit/Windows 7 32/64 Bit
• Admin rights for installation
Additional memory capacity is 
required for:
• Acrobat Reader 7
• Microsoft Internet Explorer from 
version 6

System requirements for the 
Software Client

• Operating system Windows XP/
Vista 32/64 Bit/Windows 7 32/64 Bit
• Pentium IV from 2 GHz or 
compatible CPUs
• at least 1 GB RAM (64 Bit at least 
2 GB)
• Graphics card with at least 
1024 x 768, 128 MB and 16 bit 
colour depth MPEG 4 capability
• 100 Mbit Ethernet card
• Sound card
• Microsoft DirectX 9.0c or newer
• Microsoft Internet Explorer from 
Version 6.0 to read the help

Speech quality

The audio quality (speech transmis‑
sion) is highly dependent on the 
quality of the audio components 
built into the PC (headset, handset 
and sound card).

1  System description

DoorCom IP

Siedle DoorCom IP links the Siedle 
world of building communication to 
the IP world.
Door calls are transformed via the 
DoorCom IP and transmitted via the 
IP network to certain PCs. If video 
cameras are fitted at the door sta‑
tion, the picture of the visitor is addi‑
tionally transmitted. The DoorCom 
IP Software Client is used here as a 
virtual in‑house telephone for com‑
munication to the door station.
The Software Client must be 
installed on every PC in the network 
which is intended to receive a door 
call. 
Assignment of door calls to the 
Software Clients takes place using 
an IWA address (Interface Working 
Address) which is entered in the 
DoorCom IP with the aid of the con‑
figuration software.

DCIP 740‑...

The DoorCom IP 740‑... serves as 
an interface between a Siedle Multi 
system and an IP network.

The DoorCom IP is able to display 
the picture on the PC monitor in 
conjunction with the Siedle Software 
Client and at the same time hold the 
door call via the PC.
The door call can optionally also 
be held over the telephone system 
using a telephone, while the picture 
is displayed by the Software Client 
and all control functions such as 
door release can also be initiated by 
the software. For this, a DCA 740‑01 
must additionally be connected to 
the DoorCom IP. The video camera 
picture continues to appear in the 
Software Client on the PC monitor.

Electrical voltage

Mounting, installation and servicing 
work on electrical devices may only 
be performed by a suitably qualified 
electrician. Failure to observe this 
regulation could result in the risk of 
serious damage to health or fatal 
injury due to electric shocks.
• When working at the device, 
observe the remarks relating to 
mains cut‑off.
• Observe the standard 

 

DIN EN 60065!
• When establishing the electronic 
connection, observe the require‑
ments of VDE 0805 /EN 60950.
• The building installation must 
include an all‑pole mains switch 
with a contact separation of at least 
3 mm.
• Ensure maximum fusing of 16A for 
the mains connection in the building 
installation.
• When planning, the required 
distributor space for switch panel 
mounted devices must be taken into 
account.
• External voltages >30 V AC/ DC 

 

must not be injected into the 
inhouse telephones.

Devices with 230 V connection

In accordance with DIN VDE 0100 
Part 410, Section 411.1.3 ensure 
that the DoorCom installation and 
the mains voltage are securely iso‑
lated. The sheathing of the connec‑
tion cable (safety extra‑low voltage) 
should only be stripped back far 
enough to ensure that reliable con‑
nection is possible.

For mains connection and network 
settings such as assignment of the IP 
address, the responsible network 
administrator must be consulted.

2  Safety remarks
System requirements

Содержание DoorCom IP Multi DCIP 740 Series

Страница 1: ...DCIP 740 01 Manual DoorCom IP Multi...

Страница 2: ...P video server 10 Software 11 Siedle Multi 12 5 Installation Terminals DCIP 740 13 LED displays 14 Block diagrams 16 Wiring diagram Siedle Multi 18 6 Commissioning 21 DCIP 740 Siedle Multi 21 Multicas...

Страница 3: ...ess which is entered in the DoorCom IP with the aid of the con figuration software DCIP 740 The DoorCom IP 740 serves as an interface between a Siedle Multi system and an IP network The DoorCom IP is...

Страница 4: ...es tinations i e Siedle Multi system addresses can be assigned to the interface SIM 740 These cor respond to the functions of the 4 Multi telephones The call destina tion can be dialled from every doo...

Страница 5: ...6 cores Actuation of the link between the SIVS 610 and the IPVS 600 takes place via the patch cable Performance features Transmission of door calls with without video via the Ethernet to PC users Fre...

Страница 6: ...ead use in computer networks IP forms the first layer of the Internet protocol family which is independent of the transmission medium This means that computers can be grouped within a network into log...

Страница 7: ...work protocol which belongs to the transport layer of the Internet protocol family It is the task of the UDP to assign data transmitted via the network to the right application USB The universal seria...

Страница 8: ...c signal which sounds on button assignment The call button modules are connected to the TME 645 by means of a ribbon cable Dimensions 99 x 99 mm TM 612 1 to 4 Call button modules potential free button...

Страница 9: ...tue 20 C to 70 C Dimensions 99 x 99 mm AEM 645 0 Alphabetical input module with keypad A I Input unit for alpha numerical selection of PC users For use in Siedle Multi systems only in conjunction with...

Страница 10: ...bus line rectifier BNG BVNG 650 Commissioning programming and servicing facility for the In Home bus using BPS 650 software IPVS 600 01 System interface video server Processing and adjustment of audio...

Страница 11: ...PC monitor For each installation of the Software Client on a PC a licence is required for the DCIP SC 600 0 DCIP CO 600 0 DoorCom IP configuration software PC program for set up and program ming of th...

Страница 12: ...te several Multi telephones depending on the operating mode Only one of these virtual tel ephones can ever be active at one time i e conduct a call Dimensions 107 x 89 x 60 mm VMS 641 0 Video monitor...

Страница 13: ...VS 610 g Card slot for SDTM card no func tion h Audio Line In Audio Line Out to the SIVS 610 i LED operating status lights up in green on readiness for operation j Reset button to recreate the as deli...

Страница 14: ...low flashing OFF Display a connection exists Fast flashing OFF A software update or reconfiguration process is under way Fault LED green LED red Function OFF Slow flashing ERROR software running only...

Страница 15: ...nd LED ACT on the underneath LED Power Function OFF IPVS 600 is switched off Lights up in green IPVS 600 is switched on Flashes green Access to the IPVS 600 Lights up in red briefly Start process runn...

Страница 16: ...max 300 mA Da Db Vario Bus Supply voltage 24 V DC T not used T DR via TLC 640 02 Li not used USP Universal Serial Port SN1 RF signal path SN2 SIM 740 SIVS 610 n1 n2 RF signal for connected DCA 740 01...

Страница 17: ...Actuation from door loudspeaker for camera on With DoorCom IP the contact is permanently active Potential is switched via the UPS terminal VKA Actuation of camera distributor M is switched A1 A1 Pote...

Страница 18: ...18 5 Installation DCIP 740 Siedle Multi Camera assignment mode...

Страница 19: ...19 Monitor assignment mode...

Страница 20: ...a large number of PC users Monitor assignment mode Up to a maximum of 4 call des tinations i e Siedle Multi system addresses can be assigned to the interface These correspond to the functions of the...

Страница 21: ...i Step 1 Issue of the IP address and subnet mask in the IPVS 600 The connection can be established using a crossover network cable The IPVS 610 can also be addressed via the network if the PC and IPVS...

Страница 22: ...sh to be able to reach the SIM 740 or the relevant PC users The master monitor address is already entered The DCIP Software Client is the PC on which a Siedle in house tel ephone is depicted by the so...

Страница 23: ...video input and each stream Multicast address video 1 Enter a valid multicast address for each stream of the relevant encoder video input which you wish to work in the multicast mode dupli cation of...

Страница 24: ...ents for configu ration software DCIP CO 600 0 PC with Intel Pentium III from 1 GHz or comparable processor at least 512 MB RAM min 25 MB hard disk memory USB port or serial port depending on which PR...

Страница 25: ...ered IWA addresses can be assigned to the call buttons at inputs E1 E4 if these are used Write the configuration to the SIVS 600 with Send configura tion In the menu File DCIP generate the SC file for...

Страница 26: ...rectX 9 0c or newer Microsoft Internet Explorer from Version 6 0 to read the help Procedure for installation Install the DCIP SC 600 software It may be necessary to install addi tional programs such a...

Страница 27: ...ff If there is an active firewall the application file DCIP SC 600 0 exe must be defined as an exception or as a permanently authorized program application In order to establish a video link it may be...

Страница 28: ...lection SW1 OFF 0 dB as delivered status ON 9 dB 7 Setting the speech volume Level adjustment DCIP 740 Level adjustment TLM 645 Setting the volume of the PC user from the door station in the direc tio...

Страница 29: ...is supplied from the telecommunication system or the a b public network connection from the exchange It is not possible to connect an individual public network telephone directly to the a b line of th...

Страница 30: ...r 7 Siedle Multi 4 17 Software Client 23 Subnet mask 7 System interface video server 9 System requirements 23 25 TCP 7 Terminals 15 UDP 7 Vario bus 7 Web browser 20 Wiring diagram 17 10 Glossary Index...

Страница 31: ...31...

Страница 32: ...efon und Telegrafenwerke OHG Postfach 1155 78113 Furtwangen Bregstra e 1 78120 Furtwangen Telefon 49 7723 63 0 Telefax 49 7723 63 300 www siedle de info siedle de 2012 07 01 Printed in Germany Best Nr...

Отзывы: