EC 602-…
Control functions
/
Access control
-
TCIP 603-…
Control functions
/
Access control
1+n technology
RC 602-…
Direct call of the indoor stations
In-Home bus
BIM 650-…
Direct call of the indoor stations
Multi
TLC 640-…
Direct call of the indoor stations
/
Control functions
/
Access control
Access
-
Direct call of the indoor stations
Application
Code lock module as input unit for
access control and for making door
calls.
Depending on the functional scope
of the access control and the
intercom system, further devices are
required for management and con-
trol functions.
• LED as status indicator, only for
Vario (external potential-free con-
tact)
• Door release button for direct door
release v
ia the EC 602…
• Control functions (e.g. roller shut-
ters)
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qu
alified
electrician.
Range
The conductor network laid
throughout the entire Vario bus
must n
ot exceed 2000 m. Th
e loop
resistance (forward and return line
between the functional unit and
the control unit) must not exceed
20 Ohm. A core diameter of 0.8
mm
results in a rang
e of appr. 260 m.
The power supply to the Vario
Bus components is provided by a
separate transformer
TR 602…/
TR 603…
English
Steps must be taken to ensure that
the supply voltage never exceeds
9 V AC at any
device with maximum
current consumption.
Pilfer safeguard
In order to protect the Vario modules
from unauthorized access, the pilfer
safeguard controller
DSC 602… can
be optionally used in conjunction
with the ZD
S 601… This can be
used to protect the inserted modules
from unauthorized access.
Scope of supply
•
Code lock module COM 611…
• Terminal block
• This product information
Terminal assignment
bv, cv
Power supply 12 V AC
Da, Db
Vario bus
1,6
Triggering
Door loudspeaker
E1, E2
Connection of an
external door release
button
L1, L2
LED status display,
Potential-free input
b, c
for additional power
supply if there are a
large number of illumi-
nated call buttons
Mounting and installation
1
Address setting
If several input/read units of
the
same type (e.g.
several COM 611…
an
d/or ST 10…) are use
d in a
system, a different address must be
set on each of th
e input/read units.
• In order to change the Vario bus
address, any pre-mounted module
must be removed from the door sta-
tion’s mounting frame.
•
Open the flap on the back of the
module with the aid of a screw-
driver.
• Set
the address (1 to 8)
on the
rotary switch.
•
Once the address
has been set,
close
the flap and, if nec
essary, re-
secure the terminal block and
refit
the module.
Circuit diagrams
2
Terminal diagram access control
with EC 602-…
3
Terminal diagram access control
with TCIP 603-…
The wiring diagrams for the use of
the code lock for door calls can be
found in the system manual for the
door communication system, which
is supplied with the line
rectifier/
server.
Programming
The COM 611… is prog
rammed via
the corresponding auxiliary device.
The procedure is described in the
corresponding programming instruc-
tions.