background image

INS-TSSHC-3NPSBFS-16A-1209

For further information or to consult this guide on line, 

please visit our Web site.

“TSSHC-3NPSBFS-16A”

Heating floor non programmable 

electronic thermostat

User’s guide

www.sshcinc.com

Содержание TSSHC-3NPSBFS-16A

Страница 1: ...SSHC 3NPSBFS 16A 1209 For further information or to consult this guide on line please visit our Web site TSSHC 3NPSBFS 16A Heating floor non programmable electronic thermostat User s guide www sshcinc...

Страница 2: ...der to avoid personal injuries or proper ty damages serious injuries and potential ly fatal electric shocks All electric connections must be made by a qualified electrician accord ing to the electrica...

Страница 3: ...y have to press down the A F button to switch from one mode to the other This control method is ideal when you want a stable ambi ent air temperature without fluctuation Usually this mode is used in l...

Страница 4: ...he examples that follow Do not install the thermostat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside...

Страница 5: ...g the two screws supplied 5 Route wires coming from the wall through the hole of the mounting base and make the required connections using the Four wire installation figure and using the supplied sold...

Страница 6: ...e sensor Four wire installation 6 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the thermostat to the desire...

Страница 7: ...d the standard factory set point adjustment is 77 F 25 C The maximum floor temperature is limited to 82 F 28 C Maximum floor temperature limitation At any time the floor temperature both in Floor and...

Страница 8: ...um floor temperature set is 82 F 28 C In Day mode you can turn off the thermostat by lowering the set point below 37 F 3 C The set point value displayed will be OFF and heating system start up will be...

Страница 9: ...own the and buttons and release them immediately Night mode timer The Night mode features a timer that automatically returns to the Day mode after a selectable time period This timer allows the tempor...

Страница 10: ...button to decrease it The adjustment range is from 1 hour to 999 hours To quickly scroll through timer values press and hold down the but ton 4 When the adjustment is completed release the buttons an...

Страница 11: ...8 hours at the night temperature set point Then it will return to the Day mode for 16 hours operating at the day temperature set point At the end of the 24 hour cycle the thermostat will return to the...

Страница 12: ...o activate the Automatic mode and if it was activated the Automatic mode will be deacti vated 3 Activate the Automatic mode by simultaneously pressing down the and buttons for at least 3 seconds The A...

Страница 13: ...tton to switch from the degrees Fahrenheit to the degrees Celsius and conversely The degree Fahrenheit or Celsius symbol is displayed 3 When the adjustment is completed do not press down any button du...

Страница 14: ...ing cable This feature allow to decrease the measured temperature by 0 F to 18 F 0 C to 10 C by incre ment of 1 C To do so you must 1 Press down the A F button for at least 30 seconds the actual value...

Страница 15: ...itialized either by pressing down the Test button or by disconnecting the thermo stat at the electrical panel Ground fault circuit interrupter GFCI verification It is important to verify the ground fa...

Страница 16: ...note that the SET icon will also blink after 3 seconds 3 Release the buttons The thermostat is now locked Lock deactivation 1 Cut off the power supply of the thermostat at the electrical panel 2 Wait...

Страница 17: ...timer which are saved only if the Automatic mode was not activated Please note that the Automatic mode is not automatically reac tivated when the power is restored the Automatic icon blinks to indica...

Страница 18: ...Heating is al ways on Check if the thermostat is properly connect ed Refer to the installation section 3 Heating does not run even if the ther mostat indicates it is on Check if the thermostat is pro...

Страница 19: ...load 16 A 3840 W 240 VAC 3475 W 208 VAC 1920 W 120 VAC Range of temperature 32 F to 99 F 0 C to 40 C Temperature display resolution 1 F 1 C Range of the temperature set points Ambient Mode 37 F to 95...

Страница 20: ...in hand In order for the warranty to be valid the unit must be installed and used according to instructions If the installer or the user modifies the unit they will be held respon sible for any damage...

Отзывы: