Temperature set points

The figures beside the word SET indicate the temperature set 

points  (both  in  Floor  and  Ambient  modes).  They  can  be  dis-

played in degrees Celsius or Fahrenheit (see “Display in degrees 

Celsius/Fahrenheit”).
Out of any adjustment mode, press down the + button to in-

crease the set point, or the – button to decrease it. Set points 

can  only  be  adjusted  by  increments  of  1  degree.  To  quickly 

scroll through the set point values, press and hold down the but-

ton. Both in manual and automatic modes, the (Ambient) mode 

set points can range between 37 to 95°F and can only be ad-

justed by increments of 1°F (from 3 and 35°C; by increments of 

1°C from the Celsius mode). From (Floor) mode, the set points 

can range between 37 and 82°F (from 3 to 28°C) (if the maxi-

mum floor temperature set is 82°F (28°C)).
In Day mode, you can turn off the thermostat by lowering the 

set point below 37°F (3°C). The set point value displayed will be 

OFF, and heating system start up will be impossible.

Maximum Floor Temperature Limitation

At any time, the floor temperature (in Floor mode) is maintained 

at less than 82°F (28°C) in order to avoid overheating caused by 

an excessive heating request, which could damage some ma-

terials or be detrimental for health. It is however possible to in-

crease this limit to 37°C (99°F) by increment of 1°C. To do so, 

you must:

1. Press down the A/F button for at least 20 seconds. After 20 

seconds, the actual maximum temperature will be displayed 
in  replacement  of  the  Floor  mode  set  point  and  will  blink 
during 5 seconds. Then, you can release the A/F button.

2. Press down the + button to increase this limit or – button to 

decrease it.

Regardless  of  the  maximum  floor  set  point  (Floor  mode),  the 

maximum Ambient mode set point will always be 35°C (95°F).

Содержание TSSHC-3NPSBFS-16A

Страница 1: ...SSHC 3NPSBFS 16A 1209 For further information or to consult this guide on line please visit our Web site TSSHC 3NPSBFS 16A Heating floor non programmable electronic thermostat User s guide www sshcinc...

Страница 2: ...der to avoid personal injuries or proper ty damages serious injuries and potential ly fatal electric shocks All electric connections must be made by a qualified electrician accord ing to the electrica...

Страница 3: ...y have to press down the A F button to switch from one mode to the other This control method is ideal when you want a stable ambi ent air temperature without fluctuation Usually this mode is used in l...

Страница 4: ...he examples that follow Do not install the thermostat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside...

Страница 5: ...g the two screws supplied 5 Route wires coming from the wall through the hole of the mounting base and make the required connections using the Four wire installation figure and using the supplied sold...

Страница 6: ...e sensor Four wire installation 6 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the thermostat to the desire...

Страница 7: ...d the standard factory set point adjustment is 77 F 25 C The maximum floor temperature is limited to 82 F 28 C Maximum floor temperature limitation At any time the floor temperature both in Floor and...

Страница 8: ...um floor temperature set is 82 F 28 C In Day mode you can turn off the thermostat by lowering the set point below 37 F 3 C The set point value displayed will be OFF and heating system start up will be...

Страница 9: ...own the and buttons and release them immediately Night mode timer The Night mode features a timer that automatically returns to the Day mode after a selectable time period This timer allows the tempor...

Страница 10: ...button to decrease it The adjustment range is from 1 hour to 999 hours To quickly scroll through timer values press and hold down the but ton 4 When the adjustment is completed release the buttons an...

Страница 11: ...8 hours at the night temperature set point Then it will return to the Day mode for 16 hours operating at the day temperature set point At the end of the 24 hour cycle the thermostat will return to the...

Страница 12: ...o activate the Automatic mode and if it was activated the Automatic mode will be deacti vated 3 Activate the Automatic mode by simultaneously pressing down the and buttons for at least 3 seconds The A...

Страница 13: ...tton to switch from the degrees Fahrenheit to the degrees Celsius and conversely The degree Fahrenheit or Celsius symbol is displayed 3 When the adjustment is completed do not press down any button du...

Страница 14: ...ing cable This feature allow to decrease the measured temperature by 0 F to 18 F 0 C to 10 C by incre ment of 1 C To do so you must 1 Press down the A F button for at least 30 seconds the actual value...

Страница 15: ...itialized either by pressing down the Test button or by disconnecting the thermo stat at the electrical panel Ground fault circuit interrupter GFCI verification It is important to verify the ground fa...

Страница 16: ...note that the SET icon will also blink after 3 seconds 3 Release the buttons The thermostat is now locked Lock deactivation 1 Cut off the power supply of the thermostat at the electrical panel 2 Wait...

Страница 17: ...timer which are saved only if the Automatic mode was not activated Please note that the Automatic mode is not automatically reac tivated when the power is restored the Automatic icon blinks to indica...

Страница 18: ...Heating is al ways on Check if the thermostat is properly connect ed Refer to the installation section 3 Heating does not run even if the ther mostat indicates it is on Check if the thermostat is pro...

Страница 19: ...load 16 A 3840 W 240 VAC 3475 W 208 VAC 1920 W 120 VAC Range of temperature 32 F to 99 F 0 C to 40 C Temperature display resolution 1 F 1 C Range of the temperature set points Ambient Mode 37 F to 95...

Страница 20: ...in hand In order for the warranty to be valid the unit must be installed and used according to instructions If the installer or the user modifies the unit they will be held respon sible for any damage...

Отзывы: