Fig 12, bipolarity       

 

          

Fig 13, bipolarity

 

2.5

±

2.5V (10

±

10mA) output                  3

±

2V (12

±

8mA)output 

 

Fig 14, polarity                                  Fig 15, polarity

 

0-5V

0-20mA

output

            

  1-5V

4-20mA

  outpu

     

Fig 16, bipolarity     

                 

fig 17, bipolarity

 

2.5

±

2.5V (10

±

10mA) output 

         

3

±

2V (12

±

8mA) output

 

9 Product

s Service

 

1 Installation 

1.1

 

DIN rail installation method: 

The transducer fixed on the side of the card slot and hook 

on the mounting rail; 

Pull the spring pin down; 

Clip the transducer mount on the mounting rail; 

Release the spring pin and clip the transmitter on the 

mounting rail. 

1.2

 

Screw mounting method: 

 

4mm diameter hole in the fixed plate according to the position 

of the screw hole shown in Fig. 13;   

 

  Use the screw 

Φ

3.5 to insert into hole and secure it. 

2  Products  factory  has  been  accurately  set  according  to  the 

"product  standard".  Apply  power  after  determine  the  correct 

wiring. 

3  The  maximum  wire  diameter  of  the  terminal  block  is  2mm 

(16-26AWG). Remove the 4mm  ~ 5mm insulation layer  from the 

end of the mounting wire and insert it into the terminal block, then 

tighten the screw. 

4

 

Product supply power requires the isolation voltage 

 2000VAC, 

AC ripple <10mV. Multiple transducers can share a common set of 

power  supplies,  but  the  power  circuit  can  no  longer  be  used  to 

drive  relays  and  other  can  produce  spikes  in  the  load,  in  order  to 

avoid interference signal transmission to the transducer. 

T

he transducers output 0-20mA (or 4-20mA), the RL standard is 

 

250

Ω

, and 0-5V voltage output RL standard is 

 1K

Ω

, can guarantee 

the output accuracy and linearity over the entire rated input range. 

10Example of product accuracy level verification 

1  According  to  the  definition  of  the  transducer  terminals  to  connect 
the test circuit. 

 

Fig. 18

 

2  The  test  shall  be  carried  out  under  the  following  environmental 

conditions: 

Note: 

The  voltage  output  is  measured  with  a  voltmeter  and  the 

current output is measured with an Io meter. 

2  The  test  shall  be  carried  out  under  the  following  environmental 

conditions: 

Power supply: nominal 

±

 5%, ripple 

 10mV; 

Ambient temperature: 25 

°

±

 5

°

C; 

Relative humidity: RH (45 ~ 80)%; 

The accuracy of the signal source and measurement 

instrument is 0.05% above. 

3

 

Power preheat 2min; 

4  Using  high-precision  power  signal  source  to  input  the  value  of 

voltage  and  current  and  the  corresponding  phase,

 

and  record  the 

display  data  of  calibrator,  in  order  to  ensure  the  veracity  of  the 

accuracy, please enter voltage and current signals more than 20%of 

the  product  rang.  The  current  can  be  input  using  the  ampere-turn 

method. 

5

 

Example  for  conversion  relationship  of  output  and  measured 

value: (Power factor products: Vo voltage output, Io current output, 

C power factor). 

If the output is 0-5V, then C = Vo

÷

5V; 

If the output is 4-20mA, then C = (Io-4 mA)

÷

16mA; 

If the output is 0-2.5V-5V more than 2.5V, a advance power factor 

and inductive load, C = (5V-Vo)

÷

2.5V; When output is less than 

Current output 

Voltage output 

Power supply

 