COMMAND TABLE
Command
Description
SDL <Value>
Sets the logging port to be used in the event that a ‘generic’ translation option
is used. The available ports are:
Value Port Name
0
Serial Port 1
2
Serial Port 2
4
Ethernet Socket 1
SDM <Value>
Sets the serial port to be used in for MMI setup of the buffer. If socket 0 is set
up as a TCP listener then an incoming connection on that port will
automatically become the MMI port. While the TCP link is established the
serial port control will be disabled.
Value Port Name
0
Serial Port 1
2
Serial Port 2
XLT <Value>
Use the first few letters of the mode name. (XLT ALC will select the Alcatel
4400). Enough letters need to be entered so differentiate between options
otherwise the 1st match will be selected.
Value
Logging
Mode
Description
BIN
Binary
Unformatted data – any character sequence
ASC
ASCII
Vanilla ASCII using CR / LF
ROB
RoboDog
Proprietary Security
ISD
ISDX
The ISDX PABX
ALC
Alcatel 4400 Alcatel 4400 PABX
LG
Opticon
LG Opticon PABX
STX
StxEtx
ASCII special start and end characters
AVA
Avaya
Avaya Definity – supplies option prompt
SYS
Syslog
CISCO Syslog. Can be used for any Syslog
IPS
IPS 2000
Philips Sopho IPS 2000
CPU
CPU 3000 -
4000
Philips Sopho CPU 3000 / 4000
FTP Client
The SS-76NG logs onto the PABX using IP address
FTP Server
The SS-75NG wait for the PABX to log in
Note: