COMMAND TABLE
Command
Description
MMP <MMI Listen Port>
Sets the port number for the SS-76NG that it will listen on for MMI or
NetLog connections. The command will also indicate the Socket
Mode that has been set up.
BID <Buffer ID>
This sets the buffer ID as used by UdpLog. It is an 8 character name.
If a name short than 8 characters is used then it will be padded to 8
characters with „_‟ (Underscore) characters. If non alpha numeric
characters are used they will also be replaced
with „_‟.
LLM <LAN Logging Mode>
This sets the mode of the LAN logging socket. Options are 0 (None),
1 (TCP Passive) or 2 (TCP Active)
LLL <LAN Logging LOCAL
Port>
This sets the LOCAL port number. When set to 0 in Active (client)
mode the port will be auto-selected starting from 1024. Each time a
connection is attempted the next sequential port number will be used.
LLR <LAN Logging
REMOTE Port>
This sets the REMOTE port number. It is the port number on which
the PABX will listen. It is not used if the mode is TCP Passive
(Server).
LLI <LAN Logging IP>
This sets the PABX IP address. It is the IP address of the PABX to
which the SS-76NG will connect to retrieve data.
CTRL+Z
The previously entered line will be displayed if this is the 1st
character typed. Note : Only displays line if ECHO ON
PHO
Phone Home „PHO‟
1. The technician types in the command 'PHO'
2. The SS-77 sends an 'E' record (it is the next letter and
corresponds to 'Enquire')
3. UdpLog Responds with a 0x12 (Device Control 2) character
followed by the text 'UdpLog Response' as a single 16
character UDP packet
4. Upon receipt of the packet the buffer will turn on the
DownLoad LED and then
a. Beep at full volume
b. Pause for 0.2 seconds
c. Turn off the beeper
d. Pause for 0.8 seconds
e. Repeat the above 4 steps 5 times
Initial a normal 'A' record poll sequence so that the DownLoad LED
will turn off if the buffer is not registered.
GAG <On/Off>
Enables GSM Aggressive download. When this option is enabled the
SS-76 NG will attempt to send records immediately when they are
received rather than wait for the normal 90 second cycle. The
negative impact of this is that records are sent one at a time rather in
blocks. It should only normally be enabled when performing
diagnostic work on a PABX.
CSQ
Displays the signal strength.
IME
Displays the IMEI number for the module. Only available once the
GSM module has started up.
SCI
Displays SIM Card ID. Only available once the GSM module has
started up.