PRIOR TO USE

Page 12

Contrary to popular belief, stainless steel is not truly stainless. It is corrosion-resistant, but not corrosion-

proof. The ability of stainless steel to resist corrosion is dependent upon its protective oxide layer. This 

layer must be periodically re-introduced by cleaning the stainless steel to remove any iron and surface 

contaminants and allowing the surface to react with oxygen in the atmosphere. We recommended 

passivation of your tank upon delivery, as well as setting a routine schedule for re-passivation. Your 

basic procedure would be to clean the vessel with an acid solution (nitric, phosphoric, citric, etc.) 

to remove iron or other contaminants from the surface of the stainless steel, then lightly rinse and 

allow to air dry so that oxygen can react to form the protective oxide layer. We recommend contacting 

a chemical provider to obtain the best practices for passivation of 304 stainless steel based on the 

chemical being used. 

Before use, it is important to ensure that your analog thermometer and PT100 thermo-probe are properly 

calibrated and consistent with one another. There are several ways of calibrating a thermometer and 

thermo-probe, but the simplest way is to use an ice-water mixture. When you insert your thermometer 

and/or thermo-probe into an ice-water mixture, they should read 32º F (0º C). There is a small screw 

on the back of the analog thermometer that can be adjusted to correct for error, if any. Set an off-set on 

your digital controller temperature readout to correct for any thermo-probe error.

*NOTE: In order to use your PT100 thermo-probe, you will need some type of digital temperature 

controller. We recommend our FTSs Pro Modular Temperature Controller for ultimate compatibility. The 

FTSs Pro Modular Temperature Controller and user guide can both be found at 

www.ssbrewtech.com

PASSIVATION

CALIBRATING YOUR THERMOMETER / THERMO-PROBE

Содержание Jacketed Unitank

Страница 1: ...ENGINEERING BETTER BEER Jacketed Unitank ...

Страница 2: ...tary Pressure Gauge 1 1 5 TC Analog Temperature Gauge 1 DIN Nut Rotatable Racking Arm w 1 5 TC Port 1 3 TC Clamp 10 1 5 TC Clamp 1 3 TC Gasket 10 1 5 TC Gasket 3 1 5 TC Butterfly Valves 1 Stainless Lower Shelf 1 1 5 TC Perlick Style Sampling Valve 1 1 5 TC Carbstone w 3 8 Ball Valve 1 1 5 TC PT100 Thermoprobe 4 Threaded Stem Adjustable Feet NOTE Certain features come preinstalled on the vessel for...

Страница 3: ...P PRV CIP PORT 1 5 TC PRESSURE GAUGE A 3 TC Pressure Release Valve PRV G 1 5 TC Pro Sanitary Pressure Gauge B 3 TC Gasket H 1 5 TC Gasket C 3 TC Clamp I 1 5 TC Clamp D 8 or 12 TC Lid E 8 or 12 TC Lid Gasket F 8 or 12 TC Lid Clamp A G B H C I D E F Page 3 ...

Страница 4: ...TANK FEATURES ASSEMBLY J 1 5 TC Blow Off Arm H 1 5 TC Gasket I 1 5 TC Clamp K Clamp L Butterfly Valve J H I K K H I L Page 4 1 5 TC BLOW OFF ARM W BUTTERFLY VALVE ...

Страница 5: ... 5 TC CARBONATION STONE WITH 3 8 BALL VALVE 1 5 TC ANALOG TEMPERATURE GAUGE M 1 5 TC Carbstone w 3 8 Ball Valve M 1 5 TC Analog Temperature Gauge H 1 5 TC Gasket H 1 5 TC Gasket I 1 5 TC Clamp I 1 5 TC Clamp M M H H I I Page 5 ...

Страница 6: ...EATURES ASSEMBLY 1 5 TC PERLICK SAMPLE VALVE 1 5 TC THERMOPROBE N 1 5 TC Perlick Style Sampling Valve O 1 5 TC Thermowell Probe H 1 5 TC Gasket H 1 5 TC Gasket I 1 5 TC Clamp I 1 5 TC Clamp N O H H I I Page 6 ...

Страница 7: ... RACKING ARM 1 5 TC BUTTERFLY DUMP VALVE L 1 5 TC Butterfly Valve L 1 5 TC Butterfly Valve H 1 5 TC Gasket H 1 5 TC Gasket I 1 5 TC Clamp P DIN Nut Rotatable Racking Arm w 1 5 TC Port I 1 5 TC Clamp Q Elbow L L H H I I Q H I P Page 7 ...

Страница 8: ...TANK FEATURES ASSEMBLY STAINLESS STEEL SHELF FEET R Stainless Steel Shelf S Threaded Stem Adjustable Feet R S S Page 8 ...

Страница 9: ...TANK FEATURES ASSEMBLY 1 2 NPT GLYCOL RETURN LINE PORT 1 2 NPT GLYCOL SUPPLY LINE PORT T 1 2 NPT Glycol Return Line Port U 1 2 NPT Glycol Supply Line Port Page 9 T U ...

Страница 10: ...acle and plug back in to the PT100 Thermoprobe Secure assembly with screw 1 Disconnect unplug units from any power outlets 2 Remove screw and unplug receptacle from the PT100 Thermoprobe 3 Use the flat head screwdriver slot to remove face of receptacle 4 Feed temperature sensor wires through receptacle WIRING INSTRUCTIONS 1 2 MSD 3 3 10A 250V 2 2 3 1 1 5 TC PT100 Thermoprobe Plug Receptacle Screw ...

Страница 11: ...serious bodily injury or death Always assume contents are under pressure This vessel has been designed and tested to con form with widely accepted beer serving and carbonating pressures Never exceed the pressure threshold of 30 PSI and never operate the vessel without the PRV in place Never use the vessel in a manner than is otherwise directed Always keep out of reach of children WARNING PRIOR TO ...

Страница 12: ...mical provider to obtain the best practices for passivation of 304 stainless steel based on the chemical being used Before use it is important to ensure that your analog thermometer and PT100 thermo probe are properly calibrated and consistent with one another There are several ways of calibrating a thermometer and thermo probe but the simplest way is to use an ice water mixture When you insert yo...

Страница 13: ...ly and with the utmost attention to safety Organic soil loads are most effectively cleaned using an alkaline cleaning agent PBW Powdered Brewery Wash has become the go to cleaning product for many homebrewers It is relatively safe to use and effective on light medium soil loads Professional breweries on the other hand tend to use some type of non chlorinated caustic for cleaning purposes Caustic i...

Страница 14: ...REV 02112019 SsBrewtech com ...

Отзывы: