POWERING THE FTSs PRO

The FTSs Pro Modular Temperature Controller comes with a lead marked “110~240VAC-in”. The 

three wires in this cable correspond to hot (brown wire), neutral (blue wire), and ground (green/yellow 

wire). A plug is purposely omitted from the cable to accommodate various methods used for supplying 

110~240VAC to the unit. If you are installing a plug, 

BE SURE that a GFCI breaker/receptacle is 

installed.

SETUP

Temperature

OFF

Run

Crash

110~240VAC-In

Brown - Hot

Blue - Neutral

Green/Yellow - Ground

To Temperature Sensor

Solenoid Connection

SENSOR INSTALLATION

The FTSs Pro Modular Temperature Controller comes with a lead marked “Sensor”. The two wires in 

this cable (red and black) will connect to your temperature sensor. If you are using an Ss Brewtech 

vessel, your tank comes equipped with a PT100 platinum resistance thermometer. The red and black 

wires will connect to terminals 1 and 2 on the thermometer’s plug. The orientation of the wires does not 

matter, as long as they are connected to terminals 1 and 2. 

SOLENOID INSTALLATION

The FTSs Pro Modular Temperature Controller comes with either a ½” (1-3.5 bbl Unitank) or ¾” (5 bbl 

and larger Unitank) electric solenoid valve. Installation can be handled in a variety of ways based on 

preference and setup. We recommend installation of a manual bypass piping/valve arrangement, as 

well as piping/valve arrangement to clear the line of glycol in the event that service is needed. 

Содержание FTSs Pro

Страница 1: ...ENGINEERING BETTER BEER FTSs Pro Modular Temperature Controller Europe ...

Страница 2: ... by using a temperature sensor to read the present value PV of your vessel and triggering an output based on the set value SV in order to match PV with SV When cooling is called for the solenoid valve will open to allow the flow of glycol through your vessel s cooling jackets or coils until the set value is achieved INTRODUCTION Temperature OFF Run Crash FTSs Pro Controller Solenoid Valve ...

Страница 3: ...r comes with a lead marked Sensor The two wires in this cable red and black will connect to your temperature sensor If you are using an Ss Brewtech vessel your tank comes equipped with a PT100 platinum resistance thermometer The red and black wires will connect to terminals 1 and 2 on the thermometer s plug The orientation of the wires does not matter as long as they are connected to terminals 1 a...

Страница 4: ...return to the primary display The input setting can be manipulated based on the type of sensor being used The correct input setting for a PT100 sensor is Cn t 1 This should be the default setting on your controller If you are reading a sensor error message S ERR double check your connections to the sensor and ensure that Cn t is set to 1 If you are using a different type of sensor see the included...

Страница 5: ...erature Setup Range Platinum resis tance ther mometer input type Platinum resistance thermometer Pt100 0 1 2 JPt100 3 4 Input type Name Set Value Input Temperature Setup Range Thermocouple input type Thermocouple K 0 1 J 2 3 T 4 17 E 5 L 6 U 7 18 N 8 R 9 S 10 B 11 Infrared 12 temperature 13 sensor 14 ES1A 15 ...

Страница 6: ... water mixture it should read 32 F 0 C Perform the ice method of calibration and document the offset if any You can then set a temperature offset on the controller to reflect this variation Press the Level Key for less than 1 second and then use the Mode Key until you see Cn5 Next use the Up or Down Key to change the temperature offset Press the Level Key for less than 1 second to exit to the main...

Страница 7: ...then press the Mode Key until you see d U Press the Up or Down Keys to toggle between Fahrenheit F and Celsius C The FTSs Pro Modular Temperature Controller allows you to set a hysteresis value This value represents the number of degrees away from the set value that the Omron will trigger an output Press the Level Key for 3 or more seconds and then press the Mode Key until you see HYS Press the Up...

Страница 8: ... if you wish to have finer temperature control or if you are using a smaller hysteresis value Press and hold the Level Key for less than 1 second and then press the Mode Key until you see dP Use the Up or Down Keys to move the decimal points Press the Level Key for less than 1 second to exit Up Key Level Key Down Key Mode Key No 1 Display No 2 Display ...

Страница 9: ...ontroller and the solenoid valve will open When the set value is achieved OUT will disappear from the display and the solenoid valve will close When in Crash mode the user can quickly toggle to a programmable crash temperature 0 C for example The controller will memorize this temperature and by simply turning the switch you can switch to this temperature without toggling the up and down keys Tempe...

Страница 10: ...REV 04182019 SsBrewtech com ...

Отзывы: