( 8 / 12)
5.
Output connectors wiring
5.1 Harting6 LV hoist connector
5.2 Remote connector *optional
Neutrik NC5-MAH/FAH
Connectors are used for link operation of units. Up to 30 units can be linked and in local operation
mode their control is via one GO and E-STOP button
Pin
Function
note
1
Data CMN
Data Common
2
Data -
Data Minus
3
Data+
Data Plus
5.3 Loadcell E-STOP connector *optional
Neutrik NC4-FAH
Pin
Function
note
1
DC24-36V
Connected to 3
2
Active 1
Active line 1
3
DC24-36V
Connected to 1
4
Active2
Active line 2
Both safety lines are separate and NO /normally open/. For loadcell E-STOP activation contacts need
to go to NO /normally closed/ state for E-STOP activation.
For reset a loadcell e-stop function please cycle the E-STOP mushroom on device.
Pin
Function
Note/signal
1
Live L1
brown
2
Live L2
black
3
Live L3
gray
4
Control COMMON
5
Control UP
6
Control DOWN
Ears/body
Earth
Yellow/Green