background image

SRS Quick Start

SOFTWARE USER MANUAL

General safety and hazard warnings for all Dewesoft systems

Safety of the operator and the unit depend on following these rules.

Use this system under the terms of the specifications only to avoid any possible danger.

Read your manual before operating the system.

Observe local laws when using the instrument.

DO NOT touch internal wiring!

DO NOT use higher supply voltage than specified!

Use only original plugs and cables for harnessing.

You may not connect higher voltages than rated to any connectors.

The power cable and connector serve as Power-Breaker. The cable must not exceed 3 meters, the
disconnect function must be possible without tools.

Maintenance must be executed by qualified staff only.

During the use of the system, it might be possible to access other parts of a more comprehensive
system. Please read and follow the safety instructions provided in the manuals of all other
components regarding warning and security advice for using the system.

With this product, only use the power cable delivered or defined for the host country.

DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a
voltage supply unit.

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth
terminal), a non-interruptible safety earth ground must be provided from the mains power
source to the product input wiring terminals.

Please note the characteristics and indicators on the system to avoid fire or electric shocks.
Before connecting the system, please read the corresponding specifications in the product
manual carefully.

The inputs must not, unless otherwise noted (CATx identification), be connected to the main
circuit of category II, III and IV.

The power cord separates the system from the power supply. Do not block the power cord, since
it has to be accessible for the users.

DO NOT use the system if equipment covers or shields are removed.

If you assume the system is damaged, get it examined by authorized personnel only.

Adverse environmental conditions are Moisture or high humidity Dust, flammable gases, fumes
or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic
fields, etc.

The measurement category can be adjusted depending on module configuration.

Any other use than described above may damage your system and is attended with dangers like
short-circuiting, fire or electric shocks.

The whole system must not be changed, rebuilt or opened.

DO NOT operate damaged equipment: Whenever it is possible that the safety protection features
built into this product have been impaired, either through physical damage, excessive moisture,
or any other reason, REMOVE POWER and do not use the product until the safe operation can be
verified by service-trained personnel. If necessary, return the product to Dewesoft sales and
service office for service and repair to ensure that safety features are maintained.

If you assume a more riskless use is not provided anymore, the system has to be rendered
inoperative and should be protected against inadvertent operation. It is assumed that a more
riskless operation is not possible anymore if the system is damaged obviously or causes strange
noises. The system does not work anymore. The system has been exposed to long storage in
adverse environments. The system has been exposed to heavy shipment strain.

SRS Shock Response Spectrum V21-1

15/17

Содержание DEWESoft X

Страница 1: ...SRS Quick Start Manual SOFTWARE USER MANUAL SRS Shock Response Spectrum V21 1 1...

Страница 2: ...ibration 12 Support 13 Service repair 13 Restricted Rights 13 Printing History 13 Copyright 13 Trademarks 13 Safety instructions 13 Safety symbols in the manual 14 General Safety Instructions 14 Envir...

Страница 3: ...d on the acceleration time history It applies an acceleration time history as an excitation to an array of single degree of freedom SDOF systems Each system is assumed to have no mass loading effect o...

Страница 4: ...cy spectrum The upper limit is set to 1 2 of MAX sampling rate Velocity DC filter removes the DC component of the calculated time signal InputChannel VelocityHistory Frequency division octave defines...

Страница 5: ...esponse and very high damping produces a horizontal line The standard value for relative damping of 5 results in a Q quality factor of 10 Remove DC offset in milliseconds removes the DC component of t...

Страница 6: ...noise floor of the input time signal The noise floor will be calculated the defined time interval behind the position of the first cursor c Results The results in frequency domain spectrum can be sho...

Страница 7: ...for both instances The composite shock response for the absolute maxima is the maximax Absolute max during shock primary forced response computation during the shock Max during shock primary forced re...

Страница 8: ...art SOFTWARE USER MANUAL After that the cursors I and II need to be locked with the click on the buttons After the cursors are locked they change the colour in the recorder SRS Shock Response Spectrum...

Страница 9: ...ndicates our position in the timeline of the datafile has to be placed at the beginning of the shock b Setup the calculation parameters The next step is to define the calculation parameters frequency...

Страница 10: ...he data c Displaying the results The results of the spectrum are calculated in frequency domain and can be displayed on 2D graph ChannelName VelocityHistory is a time channel displayed on the recorder...

Страница 11: ...SRS Quick Start SOFTWARE USER MANUAL SRS Shock Response Spectrum V21 1 11 17...

Страница 12: ...RRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Dewesoft shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any...

Страница 13: ...ged 23 July 2018 at 16 54 Copyright Copyright 2015 2019 Dewesoft d o o This document contains information which is protected by copyright All rights are reserved Reproduction adaptation or translation...

Страница 14: ...ation about the environmental impact of the product Product End of Life Handling Observe the following guidelines when recycling a Dewesoft system System and Components Recycling Production of these c...

Страница 15: ...l carefully The inputs must not unless otherwise noted CATx identification be connected to the main circuit of category II III and IV The power cord separates the system from the power supply Do not b...

Страница 16: ...cations Use measurement leads or measurement accessories aligned with the specification of the system only Fire hazard in case of overload Lithium ion batteries are classified as not hazardous when us...

Страница 17: ...xample in the process industry or in environments with potentially explosive atmospheres are excluded from the scope of this product family standard IEC 61326 3 1 Devices and systems according to IEC...

Отзывы: