This menu is contained in and supplementary to information of the main menu)

      In the "main menu", tap "     " to enter into this menu; continue to tap "      ,      " to switch between 
menus;or tap "    " to return to the "main menu".

Displayed item/ 

parameter

Description

Remarks

1

ChagState:

IDLE

Charging state indications:

"

IDLE

",

no charging

"

MPPT

",

MPPT charging

"

EQU

",

equalizing charging

"

BST

",

boost charging

"

FLT

",

floating charging

"

LIMIT

",

current-limited charging

BatVol

11.6V

Battery voltage

PvVol

0V

Solar panel voltage

ChagCrt

0A

Charging current

2

LoadState

OFF

Load in "ON" or "OFF" state

LoadCrt :

0A

Load current

BatSoc

100%

Remaining battery capacity

DevTemp

27

Controller temperature

3

ChagPower

0W

Charging power

LoadPower

0W

Discharging power

MinBatVol

12.5V

The current day's min. battery voltage

MaxBatVol

13.0V

The current day's max. battery voltage

4

Fault

NULL

DEV

-

OVRTMP

BAT-OVRTMP

PV

-

OVP

PV

-

OC

-

OVD

PV

-

MP

-

OVD

Not every 
controller has 
all of these 
error codes. 
For details, 
refer to the 
User Manual 
of the 
correspondin
g controller.

PV

-

REV

Controller error codes:

BAT

-

LDV

over-discharge

BAT

-

OVD

over-voltage

BAT

-

UVW

 under-voltage warning

L

-

SHTCRT

 load short-circuit

L

-

OVRCRT

 load over-current

 internal over-temperature

battery over-temperature 

solar panel overpower

solar panel over-voltage
solar panel working over-voltage

solar panel reverse-connection

Page

2nd-level 

menus

Menu level

Definitions of "main menu" icons

Icon or value

State

Description

Remarks

Steady on

"

0~100%"

"

0%"

in slow 

flashing

"

100%"

in quick 

flashing

Nighttime

Daytime

A dynamic arrow indicates charging is in process, 
while a static one indicates otherwise.

Current battery capacity

Battery over-discharged

Battery over-voltage

A bulb shown as left and a dynamic arrow indicate the 
load is switched on.

A bulb shown as left and a static arrow indicate 
the load is switched off.

Overload or short-circuit protection

Day or night indicating icon

Charging current icon

Battery icon and SOC

Load current icon

Load icon and state indication

charging power

load current

Battery voltage

37%

26.8V

11.6V

0W

0A

OFF

0A

37%

Related to 

charging

Related to 

battery

Related to 

load

Solar panel voltage

charging current

Load state

Steady on

Steady on

Steady on

Steady on

Quick flashing

3.3.2 Main Menu

3.3.3 Real-Time Monitoring

11

12

Содержание ML4860N15

Страница 1: ...er User Manual Model Battery voltage Max solar panel voltage Max input power Charging current Discharging current ML4860N15 12V 24V 36V 48V 150V 25 C 145V 25 C 800W 12V 1600W 24V 2400W 36V 3200W 48V 60A 20A Specification version number V1 02 If there is any change without notice Code 103757 ...

Страница 2: ...cause damage Tips means advice or instruction for the operator Table of Contents 1 Product Introduction 1 1 Product Overview 1 2 Product Features 1 3 Exterior and Interfaces 1 4 Introduction to Maximum Power Point Tracking Technology 1 5 Charging Stages Introduction 2 Product Installation 2 1 Installation Precautions 2 2 Wiring Specifications 2 3 Installation and Wiring 3 Product Operation and Dis...

Страница 3: ...istorical data storage function is available and data can be stored for up to a year The controller is equipped with an LCD screen with which users can not only check device operating data and statuses but also modify controller parameters The controller supports standard Modebus protocol fulfilling the communication needs of various occasions All communications are electrically isolated so users ...

Страница 4: ...f the charging stages MPPT can t be used alone but has to be used together with boost charging floating charging equalizing charging etc to complete charging the battery A complete charging process includes fast charging sustaining charging and floating charging The charging curve is as shown below a Fast charging At the fast charging stage as the battery voltage has not reached the set value of f...

Страница 5: ...nstalling the battery For open lead acid batteries wear a pair of goggles during installation and in case of contact with battery acid flush with water immediately In order to prevent the battery from being short circuited no metal objects shall be placed near the battery Acid gas may be generated during battery charging thus make sure the ambient environment is well ventilated Keep the battery aw...

Страница 6: ...ys be careful in operation First connect the battery then the solar panel and finally the load When wiring follow the order of first and then Power on After connecting all power wires solidly and reliably check again whether wiring is correct and if the positive and negative poles are reversely connected After confirming that no faults exist first close the fuse or breaker of the battery then see ...

Страница 7: ...e current day Device information Bluetooth connection state This menu is available only to the display units with the optional bluetooth function Refer to Usage of Navigation Keys for operations including entering into and exiting each of the above menus related parameters setting etc 3 3 LCD Display and Operations 3 3 1 Menu Block Diagram 9 10 Return to previous menu exit without saving Enter int...

Страница 8: ...des BAT LDV over discharge BAT OVD over voltage BAT UVW under voltage warning L SHTCRT load short circuit L OVRCRT load over current internal over temperature battery over temperature solar panel overpower solar panel over voltage solar panel working over voltage solar panel reverse connection Page 2nd level menus Menu level Definitions of main menu icons Icon or value State Description Remarks St...

Страница 9: ... BstChgVol 9 0 17 0V 3 Floating charging voltage FltChgVol 9 0 17 0V Boost charging recovery voltage BstChgRev Over discharge recovery voltage LowVolRev Under voltage warning level UndVolWrn 4 Over discharge voltage LowVolDsc Over discharge time delay LVD Delay 0 60s 1 Equalizing charging time Equ Time 0 300 MIN 1 Boost charging time Bst Time 0 300 MIN 1 5 Equalizing charging interval Equ Inv 0 30...

Страница 10: ... the load mode setting 3 Press and hold in any menu but not the setting mode if the current load mode is manual mode pressing and holding the key will switch on off the load if the current load mode is not manual mode pressing and holding the key will cause the display to skip to the load mode setting interface and a reminder will pop up telling the user in this mode pressing and holding the key w...

Страница 11: ...ction problem gets solved normal operation will resume Load overpower protection When the load power exceeds the rated value the load will cut off output after a time delay Load short circuit protection When the load is short circuited the controller can implement protection in a quick and timely manner and will try to switch on the load again after a time delay This protection can be carried out ...

Страница 12: ...2V default 35 C to 45 C IP32 3 6kg RS232 RS485 3000m 285 205 93mm 5 2 Battery Type Default Parameters When selecting User the battery type is to be self customized and in this case the default system voltage parameters are consistent with those of the sealed lead acid battery When modifying battery charging and discharging parameters the following rule must be followed Over voltage cut off voltage...

Страница 13: ...sion Efficiency 6 3 48V System Conversion Efficiency MPPT 24V conversion efficiency 24V battery 80 82 84 86 88 90 92 94 96 98 100 40 80 160 480 800 1200 1600 Output power W 40Vmp 60Vmp 80Vmp 90Vmp 110Vmp 110 Vmp 90 Vmp 80 Vmp 60 Vmp 40 Vmp MPPT 48V conversion efficiency 48V battery 85 87 89 91 93 95 97 99 160 320 640 1000 1250 1500 2000 2500 3000 Output power W 60Vmp 70Vmp 80Vmp 90Vmp 110Vmp 60 Vm...

Отзывы: