(Historical data including: the current day's min. battery voltage, the current day's max. battery
voltage, the current day's max. charging current, the current day's max. discharging current, the current
day's max. charging power, the current day's max. discharging power, the current day's charging amp-
hrs, the current day's discharging amp-hrs, the current day's total power generation and the current
day's total power consumption)
HISTORY
0000 AGO
BtLV
:
BtHV
:
11
.
6V
11
.
5V
Historical data icon
Historical data of day xxxx (counting backwards)
The current day's min. battery voltage is 11.5V
The current day's max. battery voltage is 11.6V
Menu level
Page
Displayed item/
parameter
Description
<
History Data>
xxxx Days Ago
1
MinBatVol: 11.5V
MaxBatVol: 11.6V
MaxChgVol : 0A
MaxLodVol:
0A
2
MaxChgPow: 0W
MaxLodPow: 0W
C-D-Chg
:
0AH
C-D-Lod
:
0AH
3
E-D-Chg
:
0kWh
E-D-Lod
0kWh
:
1
Xxxx
:
select the historical data of day xxxx
(counting backwards)
0000: the current day
0001: yesterday
0002: the day before yesterday
The selected day's min. battery voltage
The selected day's max. battery voltage
The selected day's max. charging current
The selected day's max. discharging current
The selected day's max. charging power
The selected day's max. discharging power
The selected day's total charging amp-hrs
The selected day's total discharging amp-hrs
The selected day's total power generation
The selected day's total power consumption
2st-level
menu
3st-level
menu
LOAD
OFF
<Mode>
Manual
Including total charging amp-hrs, total discharging amp-hrs, total power consumption, numbers of
operating days, over-discharges and full-charges
ANALYSI
TOTAL
DAYS: 9
LVDC :
5
Number of operating days: 9
Number of over-discharges:5
Statistics icon
Load mode setting icon
Load state
Load mode
1). If the characters displayed on top of "<Mode>" are "ON", it indicates that the load is switched on, and
"OFF" indicates the load is switched off.
2
)
. Tap " " to enter into the load setting mode, and right below the "<Mode>", the mode characters or
digits will begin to flash. Use " , " to select any one from the load modes listed in the following table,
and tap " " again to complete the load mode setting.
3). Press and hold " " in any menu but not the setting mode: if the current load mode is "manual mode",
pressing and holding the key will switch on/ off the load; if the current load mode is not "manual mode",
pressing and holding the key will cause the display to skip to the load mode setting interface and a
reminder will pop up telling the user in this mode, pressing and holding the key will not switch on/ off the
load.
4). Note: this parameter is ineffective for controllers without loads.
Load mode
Mode
characters
Description
Sole light
control mode
Light
+
On
Light control
+ time
control mode
1 to 14H
Light
+
01H
...
Light
+
14 H
Manual
mode
Manual
Debugging
mode
Debug
Normal on
mode
Normal On
The solar panel voltage is lower than the light control on voltage, and after a
preset time delay , the controller will switch on the load;
The solar panel voltage is higher than the light control off voltage, and after
a preset time delay , the controller will switch off the load.
The solar panel voltage is lower than the light control on voltage, and after a
time delay, the controller will switch on the load. From this point on, the load
will work for a preset period of time (1 to 14 hours) before being switched off.
In this mode, whether it's day or night, users can press and hold the "OK"
key to switch on or off the load; this mode is often used in some special
occasions or during commissioning.
As long as the solar panel voltage is lower than the light control on voltage,
the controller will immediately switch on the load;
As soon as the solar panel voltage gets higher than the light control off
voltage, the controller will immediately switch off the load.
This mode is usually used during system installation and commissioning.
This mode is suitable for applications requiring 24-hour operation, and after
being switched on, the load keeps outputting in this mode.
Description
Menu level
Page
Displayed item/ parameter
2
LVD
-
Count
:
0
FUL
-
Count
:
0
2nd-level
menus
1
C
-
chg
:
0AH
C
-
lod
:
0AH
E
-
chg
:
0KWH
E
-
lod
:
0KWH
Rundays
:
10D
Total charging amp-hrs
Total discharging amp-hrs
Total power generation
Total power consumption
Total number of operating days
Total number of over-discharges
Total number of full-charges
3.3.8 Load Mode
3.3.9 Statistic Data
3.3.10 Historical Data of the Current Day
15
16