Model SRV947R-BT 24 X 48 Remote Display Platform
Operating and Service Manual
Part No. MAN947R-BT_210610
Page 13 of 18
S
Instruments, Inc.
,
600 Young Street, Tonawanda, NY 14150
Tel: 716-693-5977 Fax: 716-693-5854 URL:
www.srscales.com
email:
Copyright 2021
S
Instruments, Inc.
CALIBRATION (CONT’D)
Set the Gravitational Acceleration (Optional)
NOTE
: Setting the local gravitational acceleration, “
gLOC
”, will not affect the calibration. The
local gravitational acceleration, “
gLOC
”, will become the calibrated gravitational acceleration,
“
gCAL
”
only when it is recalibrated.
a)
Select the Gravitational Acceleration from the CAL menu by pressing the Left Button
when the display shows “
grav
”.
b)
The display will show only the four digits to the right of the decimal point <9.XXXX>.
c) Set the local gravitational acceleration in m/s
2
by selecting the first digit and toggle
through the digits using the Right Button until desired value is shown. Press the Left
Button and continue the same with the remaining digits.
d) Press the Left Button to save or Right Button to toggle to "
quit
". Select "
quit
" by pressing
the Left Button to quit without saving changes.
e) Press the Left Button again to save and the display will show “
SAV’d
”.
Set the Full-Scale value
a)
Select the Full-Scale from the CAL menu by pressing the Left Button when the display
shows “
FULL
”.
b)
The display will show only the five digits <XXXX.X> with the thousand-place flashing
<1>. Select past to the next digit by pressing the Left Button.
c) Once in the hundreds-place, set the full scale value (maximum load) by toggling using the
Right Button through the digits until desired value is shown. Select the desired value by
pressing the Left Button and continue the same with the remaining digits.
d) Press the Left Button to save or Right Button to toggle to "
quit
". Select "
quit
" by pressing
the Left Button to quit without saving changes.
e) Press the Left Button again to save and the display will show “
SAV’d
”.