SR Instruments SR Scales SRV957 Скачать руководство пользователя страница 15

Model SRV957 24 X 48 Wall Mount Display Platform 
Operating and Service Manual 
Part No. MAN957_220721 

 

Page 15 of 16 

 
 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150  

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

        Copyright 2022

 

Instruments, Inc. 

 

DISPLAY MOUNTING TEMPLATE 

 

Determine installation location for scale and display, keeping in mind the display cable length is 
eight (8) feet. The display may lay flat on a desk or end table. If desired, provisions for wall mount 
have been incorporated, and can be accomplished in the manner described below. 

A.

 

The  display  should  be  installed  by  qualified  personnel.  The  mounting  hardware  provided 
will cover most wall applications. 

B.

 

Determine a position on the wall comfortable to the user. Mark the location of the two (2) 
mounting  holes  on  the  wall  (holes  are  spaced  2.5”  on  center  apart)  using  the  template 
provide below.  

C.

 

Drill the two (2) pilot holes, no larger than ¼” diameter in the locations marked. Install the 
two (2) self-drilling screw anchors. 

D.

 

Install the two (2) #8 x 1” flat head screws supplied, leaving approximately ¼” projecting 
from the wall. 

 
 

Содержание SR Scales SRV957

Страница 1: ...N957_220721 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instruments Inc SRV957...

Страница 2: ...s Inc TABLE OF CONTENTS TABLE OF FIGURES 2 PACKING CHECKLIST MODEL SRV957 3 ASSEMBLY 3 SYSTEM DESCRIPTION AND INTENDED USE 4 STORAGE AND TRANSPORTATION 6 CLEANING AND DISINFECTING 5 SPECIFICATIONS 6 D...

Страница 3: ...ll cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes are spaced 2 5 on center apart using the temp...

Страница 4: ...ology to provide accurate and repeatable weight data Six 6 identically matched transducers are strategically placed to ensure an accurate representation of the animal s weight The animal s weight is d...

Страница 5: ...ON Follow manufacturer s instruction on the proper use of commercially available disinfectants Disinfectant solutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user i...

Страница 6: ...lity SPECIFICATIONS MAXIMUM WEIGHT CAPACITY 400 lb 182 kg PLATFORM SIZE 24 in x 48 in x 2 in 61 cm x 122 cm x 5 cm DISPLAY TYPE 4 3 TFT Color LCD Resistive Touch DISPLAY RESOLUTION 0 1 lb 0 1 kg ACCUR...

Страница 7: ...eigh mode and when there is a weight value stored The ZERO button is used to zero the system before placing a patient onto the scale system and to erase the last saved weight Ensure that nothing is in...

Страница 8: ...will be displayed until the display is zeroed again or until the RECALL button is pressed again NOTE The RECALL button is not displayed when there is no stored weight or when in Continuous weigh mode...

Страница 9: ...screen press the System Settings button STEP 2 Enter password 12345 STEP 3 Press the green checkmark SETTINGS Weight Data Weight units can be set to LB or KG Display can be set to Auto Hold or Contin...

Страница 10: ...iary Display was purchased separately follow the instructions below TO PAIR A REMOTE DISPLAY STEP 1 Standing near Primary display connect power cord to remote display STEP 2 Access System Setting Menu...

Страница 11: ...ceable to NIST STEP 1 Enter the System Settings menu and select Calibrate Scale STEP 2 Remove all weight from the platform and press Done STEP 3 Place the calibrated weight on the scale Wait for scale...

Страница 12: ...splay reads LOW Ensure scale is on a level surface Check to make sure all six feet are touching ground and ensure that nothing is touching bottom or sides of platform Display reads 0 0 Ensure Signal C...

Страница 13: ...or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles...

Страница 14: ...form Operating and Service Manual Part No MAN957_220721 Page 14 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstrument...

Страница 15: ...end table If desired provisions for wall mount have been incorporated and can be accomplished in the manner described below A The display should be installed by qualified personnel The mounting hardw...

Страница 16: ...anual Part No MAN957_220721 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2022 S Instr...

Отзывы: