TROUBLESHOOTING
Problem Possible
Solutions
Swap in a known working printer and
if the problem still persists then the
problem lies with the Workstation.
Problem could be component related
on the Motherboard.
The Squirrel Diagnostic feature
available in the Squirrel
One
software
can be used in conjunction with a
Squirrel Cash Drawer Tester (SQ-
9870) to test the Cash Drawer port.
The tester consists of two LED
indicators that briefly pulse ON when
the Cash Drawer function is selected
in the Diagnostic utility. If the tester
reveals that neither one of the LEDs
is triggered then the problem could be
component related on the
Motherboard. If both LEDs pulse ON,
then proceed to other Possible
Solutions listed below.
Check to make sure that the interface
cable between the Cash Drawer and
Terminal are connected properly.
Swap in a known working Cash
Drawer interface cable.
Cash Drawer will not open.
Check to make sure the Cash Drawer
is powered.
Check that the backlight cable is
connected properly at the
Motherboard and LCD end.
Faulty or damaged backlight interface
cable or cables from the LCD itself.
LCD backlight not working or too dark.
Burnt out backlight tube(s). Note:
depending on the LCD panel, some
models permit replacing backlight
tubes in the field and some don’t.
Contact Squirrel for details or to
inquire.
5-4 Preliminary Release