SMART CELLAR INVERTER COOLING UNIT
INSTALLATION
●
Installation must be performed by qualified professionals. Otherwise, it may cause personal
injury or damage.
●
The SMART CELLAR must be installed in accordance with national and local wiring
regulations, codes and standards.
●
An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in the fixed wiring.
●
Always ensure the power supply matches with the nameplate of the SMART CELLAR.
Unstable power supply or incorrect wiring will cause malfunction. Always install the correct
power supply cables before operating the SMART CELLAR.
●
Always disconnect the power supply before proceeding with any work on the SMART
CELLAR.
●
Do not supply power to the unit before finishing installation.
●
Never install or operate SMART CELLAR with a damaged power supply cable. This must be
replaced by the manufacturer, its service agent or similarly qualified persons to avoid a
hazard.
●
The temperature of the refrigerant circuit will be high, always keep the interconnection cable
away from the copper tube.
●
The SMART CELLAR is a Class 1 electric appliance. It must be properly earthed using a
specialised earthing device installed by a professional, otherwise it may cause electric shock.