background image

1008146 Rev. A

11

READ BEFORE USING

Become Familiar With The Operation Of The Spreader Before 

You Put Material In The Hopper

•  Practice walking with the spreader, opening and 

closing the rate gate at the appropriate times.

•  Travel at a constant speed and operate the spreader 

lever position.  Remember:  Open the rate gate after 

the spreader is in motion at operating speed (about 

3 mph, or at a brisk walking pace).

•  Close the rate gate while spreader is still at 

operational speed.

Dial Setting Information

The RATE DIAL has 9 numbers with 10 stops between 

each number.  This allows for accurate control of the 

spreading rate.  The dial is set with only a turn, it will 

automatically lock into the set position.  LINE UP THE 

DIAL NUMBER WITH THE DIAL INDICATOR.

Rate Dial

•  The spread width ranges from 4 - 12 ft. wide 

depending on the volume/density, particle size of the 

material, and rate of travel.

•  The spread thins or feathers at the outer edges, 

eliminating sharp, "Edge Of Spread" lines which 

cause stripes and streaks.  Extra coverage can be 

given under trees and other heavy feeding areas 

without showing "Edge Of Spread" lines.

•  Gaps and double overlaps are less likely.  Small 

errors in travel are forgiven and do not show.

WARNING:

  When spreading products containing 

herbicides, exercise extreme caution with respect to 
careless spreading and to wind-drift.

Contact Of Some Products On 

Some Plants Can Be Fatal

If a dial setting is not found, use the size and weight 

comparison table found in this manual.  Determine a 

dial setting on the low side.  If the setting proves to 

be too low, cover the area more than one time.  A 

higher setting can be used when a proven dial setting is 

established.

Remember:  

Published dial settings are 

approximate only.  The operation of the spreader, the 

condition of the material (damp or dry or over-pulverized) 

and weather conditions, are all contributing factors.  

For these reasons, it is often a good idea to spread the 

area 2 times - or one-half rate - in cross directions (SEE 

INFORMATION ON ONE-HALF RATE DIAL SETTINGS).  

One-half rate dial settings are highly recommended under 

damp and humid conditions.

Rotary Agitator

Use the rotary agitator only if needed.  Free-flowing, 

lump-free materials will not require the agitator.  The 

rotary agitator is easily installed or removed.  Note the 

clockwise rotation and sweep.  Place felt washer around 

spinner shaft before inserting agitator.

       

Now You Are Ready To Put 

Material In The Hopper

WARNING:

  Avoid Injury!  Chemicals can be 

dangerous.  Avoid injury to operators or bystanders.

•  Make sure the rate gate is in the closed position.

•  Read chemical container label for handling 

instructions.  A Material Safety Data Sheet (MSDS) 

should be supplied by the chemical dealer and 

provides proper safety information.

Содержание P30 Series

Страница 1: ...nly Hardy Co Model P30 S30 Series Spyker Spreaders Contact Us at 800 972 6130 This manual contains information for the safety of persons and property Read it carefully before assembly and operation of the equipment IMPORTANT Operator s Manual ...

Страница 2: ... 10 8 13 14 11 9 12 39 18 11 15 4 19 53 17 16 5 54 6 2 7 2 50 2 55 55 52 22 55 2 7 44 60 55 1 7 1 2 1 1 7 7 56 47 57 59 57 59 43 43 3 2 48 7 49 58 7 2 56 46 45 39 51 55 55 55 55 Rate Gate Explosion Hopper Explosion Frame Explosion ...

Страница 3: ...1008146 Rev A 3 36 34 38 29 26 24 23 25 40 24 42 32 27 31 28 30 27 28 33 37 35 Spinner Axle Explosion ...

Страница 4: ... 5 8 Gearbox Bushing 28 05 90 0094 2 3 8 Spinner Shaft Bushing 29 05 90 0096 1 3 16 x 1 Dowel Pin SS 30 05 94 0033 1 Bevel Gear 31 05 94 0034 1 Pinion Gear No Part Number Qty Description 32 05 288 1027 1 Nylon Pin Retainer 33 05 90 0097 8 10 24 x 5 8 Flange Head Bolt SS 34 05 91 0008 8 10 24 Nylon Locknut SS 35 05 94 0037 1 Gear Box Cover Front 36 05 94 0038 1 Gear Box Cover Rear 37 05 98 0111 1 G...

Страница 5: ...cations in Figure 1 One side has hole near the end of the axle the other next to the frame 3 Slide the axle bearings over the axle and into place in the frame Figure 1 4 Install a 5 8 metal washer axle spacer and a second 5 8 metal washer onto axle Figure 2 Slide wheel onto axle Repeat on other side 5 On the drive side of the axle insert the small clevis pin through the holes in the wheel and axle...

Страница 6: ...5 8 Insert 1 4 Nylon Washer onto 1 4 20 x 1 3 4 Bolt Insert through hopper and frame Attach finger tight only with 1 4 Nylon Insert Locknut Figure 5 Repeat for remaining 3 bolts washers and nuts Tighten fully 9 Slide felt washer over spinner shaft Figure 6 Insert Agitator wire by sliding through the hole in the spinner shaft as shown IMPORTANT Note orientation of agitator wire when installing Figu...

Страница 7: ...ontrol Linkage into Control Lever NOTE orientation of on off label on U shaped bracket The shorter section of linkage should face upward and away from lever as shown Figure 9 Longer Section of Linkage Shorter Section of Linkage Label 14 Install 1 4 20 x 1 1 4 Bolt and 1 4 Washer through the U shaped bracket Figure 10 15 From inside the bracket install Nylon Spacer Thick Nylon Washer then through C...

Страница 8: ...Figure 11 Install end of linkage into rate gate bracket 17 Install front of control lever assembly onto Tow Bar with 1 4 20 x 1 3 4 Bolt 1 4 Washer one on each side of tow bar and 1 4 Nylon Insert Locknut Figure 12 Do not fully tighten at this point Figure 11 Figure 12 ...

Страница 9: ...4 20 x 2 Bolt 1 4 Washers one on each side and 1 4 Nylon Insert Locknut 20 With rate gate dial set to 0 move control lever back and forth and ensure rate gate opens and closes fully Figure 14 If necessary adjust Control Lever Bracket assembly forward or necessary Fully tighten hardware from steps 17 and 19 that hold Control Lever Bracket in place 21 Install Screen into Spreader Figure 13 Rate Gate...

Страница 10: ...one sit or ride on equipment during operation Keep riders off attachment Wear substantial footwear and long trousers Do not operate the equipment when barefoot or wearing open sandals Do not wear loose fitting clothing that can get caught in moving parts Always wear eye protection when operating the equipment Stay alert for holes in the terrain and other hidden hazards Watch out for traffic when c...

Страница 11: ...xtreme caution with respect to careless spreading and to wind drift Contact Of Some Products On Some Plants Can Be Fatal If a dial setting is not found use the size and weight comparison table found in this manual Determine a dial setting on the low side If the setting proves to be too low cover the area more than one time A higher setting can be used when a proven dial setting is established Reme...

Страница 12: ...preading area or in this case approximately 3 feet or one big step Additional spreading passes will be at the full spread width or approximately 6 ft apart TAKE A SIGHTING AT THE FAR END Keep your eye on the sighting as you spread You will not need to wonder where you are or where you have been Continue until spreading is completed Left over fertilizer can be spread under trees and other high feed...

Страница 13: ...imize skewing and uneven coverage Adjustment is very sensitive Turning the Accuway Diffuser Knob just a little will result in a drastic change to the spread pattern The Accuway Diffuser Plate has a front and a rear ramp Never adjust so that the diffuser plate splits the material flow to both the front and rear ramp at the same time If the spreader is spreading to the left of center turn the diffus...

Страница 14: ...EADING CHART Product Bag Weight Sq Ft Coverage Dial Setting Full Rate Dial Setting Half Rate Spread Width Blue Grass or Red Top 5 lbs 1 000 1 25 4 1 lbs 1 000 2 0 4 2 lbs 1 000 2 5 4 Park Merion Delta or Kentucky Bluegrass 5 lbs 1 000 2 5 4 1 lbs 1 000 3 0 4 2 lbs 1 000 3 5 4 Hulled Bermuda 2 lbs 1 000 2 75 2 25 6 3 lbs 1 000 3 0 2 5 6 4 lbs 1 000 3 25 2 75 6 Mixtures Including Coarse Seeds 2 lbs ...

Страница 15: ... bent equally Using a hammer or pliers bend the feet to be equal with each other Deflector shut off is binding and will not open close properly Shut off plate is jammed with debris Thoroughly wash out hopper and shut off plates with water Ensure debris is not stuck between shut off plate and rate gate plate TROUBLESHOOTING ...

Страница 16: ...ll not be liable for any loss damage or expense including but not limited to consequential or incidental damages arising from the operation condition or use of the item The sole and exclusive remedy against Spyker Spreaders being the replacement of the defective parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state This express warran...

Отзывы: