Waukesha Cherry-Burrell
Maintenance
April 2008
95-03083
Page 31
Programming Guide: Single Seat Valves W60/W80/W90
Run Mode Display: After power up, the sensor goes automatically into run mode.
NOTE:
A green blinking LED means that the sensor was
powered up without a target present. Power down and
power up with the target present. A red blinking LED
means that the target is out of range. Re-position target
within sensing area. No LED means no output has been
triggered.
NOTE:
The P button (Position) can be used to toggle
between Red, Green, and Yellow. Use this button in case
you want to first teach Valve Open. Seatlift is not used for
Single Seat Valves. The default is set for the Closed
position (RED LED) as starting point.
NOTE:
The valve sensor can only be programmed when
assembled to a functioning valve.
Programming Steps:
A. Close Position
(RED LED)
B. Open Position
(GREEN LED)
C. Seat Wear Alarm LOWER
(RED and YELLOW LED)
D. Seat Wear Alarm UPPER
(GREEN and YELLOW
LED)
Figure 49: W60/W80/W90 Output Conditions
VA100-583
A
B
D
C
1
Press the Pos. push button for a minimum of
2 seconds.
All LED’s
flash
2x
simultaneously.
The unit is in the programming mode. Then only the
LED "
closed
" is lit. The unit is now ready for the
adjustment of the
closed
position.
2
Put the valve into the
closed
Pos. and press
the Teach button.
The LED "closed" goes out and the LED "
seat
" lights.
The unit has stored the closed position and is now
ready for the adjustment of the position
seat lift
(seat)
.
3
Put the valve into the position
seat lift
and
press the Teach button.
The LED "
open
" lights. The unit is now ready for the
adjustment of the
open
position.
4
Put the valve into the
open
position and
press the Teach button.
The LED "
open
" goes out and the LED "
closed
"
lights again. The unit has now stored all positions.
5
Press the Pos. push button for a minimum of
5 seconds. After 5 seconds, the LED "open"
flashes at about 2Hz.
After releasing, all stored measured values are
checked. If no errors are detected,
all LED’s
flash
2x
simultaneously. The unit automatically quits the
programming mode and immediately passes into the
operating mode.
If an error is found during the check, the LED
"
closed
"
flashes
at about 8Hz. Acknowledge the error
message by pressing the Pos. button and repeat the