background image

11

3, 5,

7.5 &10

15 &18

25, 30 & 35

Item#

Description

Part No.

Part No.

Part No.

1

Panel wrapper

207-303891-001

207-303891-002

207-303891-003

6

Panel Bottom

207-303881-001

207-303881-002

207-303881-003

8

Panel Front

207-303883-001

207-303883-002

207-303883-003

9

Louver

182-303884-001

182-303884-002

182-303884-003

10

Washer Shoulder

328-302074-002

328-302074-002

328-302074-002

12

Spring

276-130386-001

276-130386-001

276-130386-001

14

Terminal Box Cover

080-302079-001

080-302079-001

080-302079-001

15

Screw 10-32

248-073662-002

248-073662-002

248-073662-002

16

Fan Blade

Consult Factory

Consult Factory

Consult Factory

17

Fan Guard

134-302063-004

134-302063-005

134-302063-006

25

Enclosure

347-123273-131

347-123273-131

347-123273-131

26

Bolt 3/8-16,  1.5 lg

345-075603-263

345-075603-263

345-075603-263

27

Washer flat

328-075528-085

328-075528-085

328-075528-085

28

Washer lock

328-075571-011

328-075571-011

328-075571-011

29

Hex Nut 3/8-16

200-075473-044

200-075473-044

200-075473-044

30

Plug conduit 1/2"

221-302180-001

221-302180-001

221-302180-001

31

Plug conduit 1"

221-302180-003

221-302180-003

221-302180-003

32

Union conduit 3/4"

354-302165-001

354-302165-001

354-302165-001

33

Union conduit 3/4"

354-302243-001

354-302243-001

354-302243-001

34

Conduit Box

Consult factory

069-304115-002

069-304115-002

35

Conduit 3/4"

Consult factory

Consult factory

Consult factory

44

Plug conduit 3/4"

221-302180-002

221-302180-002

221-302180-002

50

Bolt 5/16-18

345-075603-218

345-075603-218

345-075603-218

51

Washer

328-075571-010

328-075571-010

328-075571-010

52

Nut 5/16-18

200-075473-039

200-075473-039

200-075473-039

62

Cover Exp. Proof

080-042350-007

080-042350-007

080-042350-007

75

Conduit 3/4

069-115087-049

069-115087-079

069-115087-093

1/4 HP

Motor

Heat Exchanger*

Model

Item 19

Item 49

X300812B

193-302087-006

353-304167-001

X300832B

193-302087-007

353-304167-001

X300412B

193-302087-006

353-304167-002

X300432B

193-302087-007

353-304167-002

X3004832B

193-302087-007

353-304167-005

X300632B

193-302087-008

353-304167-006

X500812B

193-302087-006

353-304167-008

X500832B

193-302087-007

353-304167-008

X500412B

193-302087-006

353-304167-009

X500432B

193-302087-007

353-304167-009

X5004832B

193-302087-007

353-304167-012

X500632B

193-302087-008

353-304167-013

X750812B

193-302087-006

353-304168-001

X750832B

193-302087-007

353-304168-001

X750412B

193-302087-006

353-304168-002

X750432B

193-302087-007

353-304168-002

X7504832B

193-302087-007

353-304168-005

X750632B

193-302087-008

353-304168-006

X1000832B

193-302087-007

353-304168-008

X1000412B

193-302087-006

353-304168-009

X1000432B

193-302087-007

353-304168-009

X10004832B

193-302087-007

353-304168-012

X1000632B

193-302087-008

353-304168-013

X1500832B

193-302087-007

353-304169-001

X1500432B

193-302087-007

353-304169-002

X15004832B

193-302087-007

353-304169-005

X1500632B

193-302087-008

353-304169-006

X1800432B

193-302087-007

353-304169-008

X20004832B

193-302087-007

353-304169-012

X2000632B

193-302087-008

353-304169-013

1/2 HP Motors

X25004832B

193-302087-009

353-304170-003

X2500632B

193-302087-010

353-304170-004

X30004832B

193-302087-009

353-304170-008

X3000632B

193-302087-010

353-304170-009

X35004832B

193-302087-009

353-304170-012

X3500632B

193-302087-010

353-304170-013

Common Parts

Motor, Element and Heat Exchanger Parts

Shown in Figure 17

Optional Equipment Parts

Description

Part Number

Thermostat

300-113075-003

15 Amp Disconnect - 3PH

104-304328-003

30 Amp Disconnect - 1PH

104-304328-004

30 Amp Disconnect - 3PH

104-304328-001

60 Amp Disconnect

104-304328-002

Pilot Light Ass’y 24V

213-121103-017

Pilot Light Ass’y 120V

213-121103-018

Pilot Lamp 24V

172-052561-004

Pilot Lamp 120V

172-052561-003

* For arctic duty conditions, heat exchanger with ethylene 

glycol are required. Consult factory.

Mounting Kit Adapter

3 through 10

027-302361-001

15 through 20

027-302361-002

25 through 35

027-302361-003

The factory must perform the
replacement of the immersion heater
or overtemperature cutout. The heat
exchanger seal must not be broken.
Consult factory for service.

RENEWAL PARTS IDENTIFICATION

 

Содержание Marley X B Series

Страница 1: ...3 43 61 420 1400 165 25 27 7 8 21 4 13 32 17 5 8 20 480 575V 3 43 68 240 1400 165 25 27 7 8 21 4 13 32 17 5 8 25 480 575V 3 54 85 300 2330 200 32 1 8 31 7 8 21 3 4 5 1 2 21 5 8 30 480 575V 3 54 102 36...

Страница 2: ...he heat exchanger is obstruct ed dirty inlet air restricted or fan not turning Shut off power to unit and refer to repair procedures section of instruction sheet 12 Mounting clearances on nameplate mu...

Страница 3: ...thermostat on interior partition walls or posts away from cold drafts internal heat sources and away from heater dis charge air streams Small rooms can be heated by one unit heater Where two walls ar...

Страница 4: ...dware 5 8 Hex Nuts Washers Cust Supplied 1 2 Mounting Hardware Bracket Spacing suitable for use with 4 U Bolts Supplied for Installation Top Bottom 5 8 Rods Length to suit 1 Min Threaded Ends Customer...

Страница 5: ...function the personnel in the area should be aware of location of heater disconnect 7 Installation must include appropriate over current protection devices fusing or circuit breakers as required by th...

Страница 6: ...t Remove this wire when using a thermostat M 3 PH Auxiliary Contactor Alarm R C1 C1 Manual Reset High Limit Control Contactor Coil Optional Factory Wiring Optional or Customer Wiring PRI PRI XFMR 120V...

Страница 7: ...s are tight and there are no cracks or looseness in the blades Use factory supplied replacement blade only 6 Check for any sign of leaking from the heat exchanger Too lit tle fluid will cause the manu...

Страница 8: ...ctions for future reference and disconnect all wires leading to the motor All motor wires are perma nently marked according to the nameplate on the motor E Remove 4 bolts in motor base holding it to r...

Страница 9: ...losure It may be replaced while in the enclosure To service or replace remove the quick connect wires and mark their locations Remove two screws which hold the transformer in place Note transformer or...

Страница 10: ...2 51 32 25 30 26 44 27 28 29 50 27 15 6 62 10 8 12 9 49 Figure 17 Electrical Control Voltage 24V 120V Contactor 072 304551 002 072 304551 008 Transformer 208 240 480 PRI 315 304252 002 315 304252 001...

Страница 11: ...53 304167 002 X3004832B 193 302087 007 353 304167 005 X300632B 193 302087 008 353 304167 006 X500812B 193 302087 006 353 304167 008 X500832B 193 302087 007 353 304167 008 X500412B 193 302087 006 353 3...

Страница 12: ...F MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREE MENT MARLEY ELECTRIC HEATING SHALL NOT BE LIAB...

Отзывы: