453261 ISS U 08.2008
19
1.
Read through the instructions before installing the pump and starting it up. If
in doubt, contact your local APV dealer.
2.
Check that the specifications of the motor and motor control unit are correct,
particularly in operating environments where there may be a risk of
explosion.
3.
Do not start the pump before all the pipe connections have been fitted care
fully and tightened, particularly those with clamp rings secured by wing nuts,
i.e. the connections on the recirculation tube and (where ordered) on the
pump inlet and outlet. If the pump is to be used for hot and/or hazardous
liquids, special precautions must be taken. In such cases follow the local
regulations for personal safety when working with these products.
4.
Do not start the pump before the motor shroud or shaft guard has been
securely fitted.
5.
The pump contains rotating parts. Never put your hands or fingers into a
pump while it is in operation.
6.
Never touch the motor or shroud during operation, as they can become very
hot.
7.
Never touch the pump body during operation if the pump is being used for
hot media where there is a risk of burning.
8.
Never close both the intake and outlet of the pump while it is in operation. If
the pump runs with liquid in it without circulation, the liquid will heat up and
may turn into vapour, causing a risk of explosion.
9.
Always remove all assembly tools from the pump before starting it up.
10.
Never hose down the electric motor directly with water or cleaning fluid.
11.
Never lift the pump in the shroud, as it is not designed to carry the weight of
the motor. Remove the shroud before lifting the pump. Always use securely
fitted lifting straps when lifting with a crane or similar lifting gear.
12.
Never dismantle the pump before the motor has been disconnected from the
power supply. Remove the fuses and disconnect the cable from the motor
terminal box.
13.
All electrical installation must be carried out by qualified staff.
14.
Never dismantle the pump until the pipe system has been drained.
Remember that liquid will always collect in the pump body. If the pump is to
be used for hot and/or hazardous liquids, special precautions must be taken.
In such cases follow the local regulations for personal safety when working
with these products.
15.
The maximum pump outlet pressure specified below must not be exceeded:
Ws+20/15: Max. 6 bar
Ws+30/30: Max. 8 bar
Ws+44/50: Max. 13 bar
The values for maximum outlet pressure apply to water at a temperature of
20°C.
16.
The risk of unauthorised tampering or inadvertent loosening by untrained
personnel of the clamp rings with wing nuts (see para. 3) should be assessed
and obviated.
0. Warnings
Содержание APV Ws+
Страница 2: ......
Страница 6: ......
Страница 17: ......
Страница 19: ...Instruction Manual Ws Pump Read and understand this manual prior to operating or servicing this product...
Страница 20: ......
Страница 22: ...453198 ISS S 03 2005 16 Ws Sectional Drawing Section 1 Shaft size 25 and 35 Section 2 Shaft size 25 and 35...
Страница 24: ......
Страница 35: ......
Страница 38: ......
Страница 43: ...34 453263 ISS T 09 2005 381340 ISS S 03 2005 7 Pumpe komplet Pump complete Standard Ws...
Страница 58: ......