30
When the plate pack has been correctly
assembled, in most models, plate edges will
create a honeycomb. So, check the edge of
the plate pack for unusual patterns before
tightening the PHE.
Check the tie bars. Brush clean and grease
over the working lengths.
Once the plate pack has been carefully
pushed towards the fixed head and then the
follower is pushed against the plate pack,
then tie bar have to be placed in their
positions
In the process below, dimension X is the final
intended compressed dimension of the plate
pack.
For small to mid sized units
(Distance between bars 1 and 3 < 1200 mm)
Compress plate pack in small increments,
moving diagonally from one tie bar to the
next. Reach final dimension X + 10% by
tightening bars 1 to 4 in the order given, in
increments of 25 mm or less. Then add all
left side and right side bars and tighten all
bars to dimension X+5% in increment of 6
mm or less. Then add the 2 top and 2 bottom
bars and compress in 3 mm increments to X.
Left s
ide
Top
Bottom
R
ight side