28
Trouble shooting
KGE/EN (1711) 6.5
If symptoms persist the pump must be taken out of service immediately.
Contact with SPXFLOW or their appointed agents.
Table 4: Possible causes of pump failures.
Possible causes
A
Wrong direction of rotatio
B
Pump not filled with liquid
C
Inlet or suction pipe insufficiently submerged
D
NPSH available too low
E
Pump not up to rated speed
F
Foreign matter in pump
G
Air leaks in suction line
H
Viscosity greater than rated
K
Gas or vapour in liquid
L
Speed too high
M
Total head lower than rated
N
Total head higher than rated
O
Viscosity and/or specific gravity higher than rate
P
Starved suction
Q
Misalignment
R
Worn or loose bearings
S
Impeller blocked or damaged
T
Bent shaft
U
Improper location of discharge valve
V
Foundation not rigid
W
Bearings badly installed
X
Pipes exert forces on pump
Y
Vibration
Z
Speed too high, check motor name plate