SPX Cooling Technologies Marley Aquatower Скачать руководство пользователя страница 3

3

/  The Marley Difference  /

Today’s Aquatower may be the most space/energy-

efficient cooling tower available. Your needs have dictated 
constant technological improvement. Thousands of 
Aquatower users enjoy the benefits of eight major redesigns 
and dozens of minor improvements in the past 40 years. For 
example, PVC film-fill enables the Aquatower to reject more 
heat per unit size. We also put the air inlet louvers and drift 
eliminators right on the fill sheets. This new arrangement 
saves you fanpower by improving airflow through the tower.

The Aquatower is a maintenance delight! You’ll 

appreciate the way the Aquatower simplifies maintenance. 
No hidden spray systems, tiny nozzles, or enclosed basins 
here! You can easily replace and align V-belts from outside 
the tower. You won’t have the chore and expense that goes 
with high-power, blower fan towers.

All primary components of the Aquatower are open to 

view. You can easily remove any debris from the upper basin 
or nozzles while the tower is in operation.

Heavy mill galvanizing on all steel components prevents 

base metal corrosion. You won’t have to worry about paint 
chips clogging your strainers and nozzles, because there is 
no paint to flake off. Heavy galvanizing also protects much 
better than paint.

Above all, the Aquatower is readily available. You won’t 

have to wait around—or accept second best—when you 
need a cooling tower. We maintain an impressive stock of 
completed towers at our own plants. A growing number of 
local distributors can draw from that stock.

Contact your local distributor or Marley representative. 

They’ll be glad to help you choose the proper model for 
your needs. They can also help you with your layout and 
piping.

You’ll enjoy single source responsibility and reliability 

because we design and manufacture virtually all major 
cooling tower components.

All Marley components are designed and selected to 

be a part of an integrated system. For example, the spray 
pattern from nozzles and the pressure drop through drift 
eliminators both affect a fill’s heat transfer capacity. So, we 
include that impact in our thermal analysis.

Drift eliminators must be effective at the air velocities 

where fill is most efficient. So, we’ve carefully designed 
both components to work together efficiently.

How many other cooling tower companies can offer 

you this assurance? They may use Brand “A” nozzles with 
Brand “B” fill and Brand “C” drift eliminators. When they all 
come together, the whole may be less than the sum of the 
parts.

Our total system approach assures that all the 

parts work together to provide you the greatest total 
performance.

And because we design specifically for cooling towers, 

all our components will provide many years of service with 
minimal maintenance.

Every Aquatower cooling tower carries a full one-year 

warranty. The Aquatower you buy from us will work on  
your job or we’ll make it right. Your warranty includes 
thermal performance and every component of the tower. 
The SPX Cooling Technologies warranty is your assurance 
of performance—for a full year.

The Aquatower has inspired many imitators. Only  

SPX Cooling Technologies can offer you the original.

Содержание Marley Aquatower

Страница 1: ...MarleyAquatower CoolingTower...

Страница 2: ...e all year long Proven Corrosion Protection Thousands of users over more than 40 years confirm the value of heavy galvanizing And Marley s Z 600 is the most effective galvanizing used in the industry...

Страница 3: ...r of local distributors can draw from that stock Contact your local distributor or Marley representative They ll be glad to help you choose the proper model for your needs They can also help you with...

Страница 4: ...et Install the desired connection and seal the unused opening with the cover plate provided Pump suction should use side outlet See page 9 for size and flow capacities of bottom outlets 7 Overflow is...

Страница 5: ...TION BASIN 16mm DIAMETER HOLES TOWER COLLECTION BASIN B NORMAL GAUGE MIN BEARING WIDTH AT EACH ANCHOR BOLT 51 SUPPORT BY OTHERS TOWER COLLECTION BASIN SUPPORTING STEEL PLAN OPTION ONE VIEW B SECTION A...

Страница 6: ...irborne trash out of the collection basin and fill area Hot water distribution basin covers are provided as standard equipment to keep the distribution basin free from airborne debris and to reduce th...

Страница 7: ...onsist of welded heavy gauge steel wire hoops and spokes hot dip galvanized after fabrication The galvanized steel belt guard encloses both belts and pulleys Guards are easily removed for servicing Co...

Страница 8: ...temperature dictates 5 Contact your Marley sales representative for selections appropriate for other ambient conditions than those shown here Indoor Tank Method In this type of system water flows from...

Страница 9: ...2 494A 494B 494C 13 6 32 507 32 3 51 5 549 51 7 85 4 613 85 6 127 8 674 495A 495B 18 6 43 6 689 43 8 61 3 727 61 5 116 5 829 116 7 173 3 912 496A 496B 23 6 44 5 863 44 7 64 9 920 65 1 112 8 1026 113 1...

Страница 10: ...stainless steel structure Or you can choose a galvanized tower with a stainless steel cold water collection basin Your Marley sales representative can help you choose the amount of corrosion resistanc...

Страница 11: ...housing with externally accessible remote oil reservoir for easy maintenance Fill Louvers and Drift Eliminator Fill shall be film type thermoformed PVC with louvers and drift eliminator formed as par...

Страница 12: ...BANK WORCESTER WR3 8AB UNITED KINGDOM 44 0 1905 720 200 info uk spx com spxcooling com In the interest of technological progress all products are subject to design and or material change without noti...

Отзывы: