System principle
GCU
SPARCIN
Air
Oxygen
Nitrogen
F5
AH35
Gas
TCU
GCU Cable
Hose parcel
TCU Cable
T
O
R
C
H
Gas Hoses
CNC
Interface
GCU/AD5
CNC/AD4
PA/AD2
TCU/AD3
Connecting the system
Note! Do not connect electricity until the very last. Parts of the system are live even if the
power switch is off!
Mount the torch connection unit TCU on an appropriate place on the robot or torch
carriage. Make sure that the torch can move without stretching or excessively bending
the hose assembly.
Mount the torch in a suitable holder on the robot or torch carriage. Make sure that the
torch head is easily accessible for replacement and that the holder is electrically
isolated from the torch. Connect the torch to the TCU. Check that the hoses are not
stretched or bent.
Connect the 25 pole control cable marked GCU-PA between the GCU contact on the
plasma power source and the contact marked Power Source or PA on the GCU.
Connect the 9-pole control cable marked GCU-TCU between the GCU and the TCU.
Mount the hose assembly TCL between the power source and the TCU. Make sure
that the hoses are not stretched, bent or twisted as this can lead to excessive wear on
the hoses and also block the coolant flow. The TCL should be drawn via the opening
in the front panel. The connection can be made by opening the side door on the right
hand side of the machine. Open the lid on the TCU and connect the cables and hoses.
Make sure that the ground cable is properly fastened.
Mount the gas hoses 1,2 and 3 between the GCU and the TCU. Be careful to avoid dirt
from entering the hoses. Make sure that there are no creases on the hoses.