SPT Labtech apricot S1 Скачать руководство пользователя страница 14

© 2021 SPT Labtech Ltd 

 

 

 

13 

2.5 

– Adjustable Plate Elevators 

 

 

2, 3 or 4 Plate Elevators available for 
individual sampling using multiple 
plates and a variety of liquid 
handling labware. 
 

 

 

 

2.6 

– Adjustable Split-Level Shuttles 

 

 

Additional flexibility and even 
greater sampling control 

 2, 3 or 4 

Split Level Shuttles available for 
individual sampling using multiple 
plates and a variety of liquid 
handling labware. 

 
 
 

 

Содержание apricot S1

Страница 1: ...apricot S1 user guide...

Страница 2: ...2021 SPT Labtech Ltd 1 Notes...

Страница 3: ...venient place Failure to adhere to proper care maintenance and operation of the instrument may lead to poor experimental results reduced equipment life and the possibility of injury to the operator We...

Страница 4: ...Repeatable Results 12 2 4 EZ Load Tip Technology 12 2 5 Adjustable Plate Elevators 13 2 6 Adjustable Split Level Shuttles 13 2 7 Accessing the Pipetting Core 14 2 8 Loading a 96 or 384 Channel Core 14...

Страница 5: ...r at 5 L 125 2 error at 1 L Resolution 1250 1000 500 1 L 125 0 1 L Volume Max channel capacity 1250 L Dispense range 1250 5 1000 L 1000 5 1000 L 500 1 500 L 125 0 5 125 L ParticleSize 0 032 diameter t...

Страница 6: ...rmance of the manufactured instrument to help you get the best results o It is highly recommended that you use disposable tips manufactured by Apricot Designs because they are designed to perform opti...

Страница 7: ...ctions Manual before you start the install process o Place the instrument on a sturdy and level surface o Use appropriate caution when operating this instrument o Verify that the ON OFF switch is in t...

Страница 8: ...back straight and lift with your legs to avoid possible injury The instrument is quite heavy so several people are required to move it Place the instrument on a steady sturdy flat and level surface L...

Страница 9: ...ch com support 8 1 4 Software Specs and Requirements System Requirements o Android System o Display Requirement Change display size to 100 ratio Inspect the instrument for any visible damage that may...

Страница 10: ...2021 SPT Labtech Ltd 9 2 Features...

Страница 11: ...ch com support 10 2 1 Applications o Plate replication o Plate reformatting o Reagent addition o Compound addition o Serial dilution by column o Inspect the instrument for any visible damage that may...

Страница 12: ...24 channel Serial Dilution Heads Inserts Serial Dilution Tips Strip Tips SP C 096 125 5 125 L SP 096 A 01 0125 125 096 EZ NS S FS SP 096 A 01 0125 SC 125 008 EZ NS S FS 050 096 EZ NS S FS 050 008 EZ N...

Страница 13: ...only takes a few seconds easily reconfigure as needed For best pipetting results consider pipette tip selection along with the pipette head that will be used 2 4 EZ Load Tip Technology The S Pipettor...

Страница 14: ...vidual sampling using multiple plates and a variety of liquid handling labware 2 6 Adjustable Split Level Shuttles Additional flexibility and even greater sampling control 2 3 or 4 Split Level Shuttle...

Страница 15: ...ge Core moves the plunger to a designated position for core exchange Accessing Core To access the core 1 remove the lock screws 2 raise the hood and 3 set the hood on the support rod Remove Lock Screw...

Страница 16: ...ptional Press Touch Screen or Quick Keys for Operation Wait for Software to Start 3 Operation Overview Care should be exercised when unpacking the crate o Inspect the instrument for any visible damage...

Страница 17: ...td sptlabtech com support 16 4 Main Screen Overview 4 1 Pipettor Control Interfaces Pipettor control is at your fingertips No external computer needed Intuitive Touch Screen Quick Access Keys See more...

Страница 18: ...light will turn ON When the operation is completed the light will turn OFF o Wait for the flashing lights to stop before pressing another function t 1 Channel Display of the number of channels in the...

Страница 19: ...y speed value via touchscreen 16 Mix Tap Mix button to execute the mix function 17 Mix Dispense Speed Display of user selected or default mix dispense speed Assign change the mix dispense speed value...

Страница 20: ...fault overshoot value 3 L Maximum value is 48 L Plunger Pause Assign the plunger pause time seconds according to user requirements Plunger pause adjustment range 1 5 seconds Liquid Class Compensate al...

Страница 21: ...ter the desired maximum tip volume Aspirate Tap Aspirate button to execute the aspirate function Mix Tap Mix button to execute the mix function Empty Blowout Tap Empty Blowout button if remaining volu...

Страница 22: ...tips clamped in the pipettor overnight Clean the unit regularly Using a clean cloth moistened with ethyl alcohol or cleanser wipe down the instrument surfaces Avoid cleaning the Touch Screen with sol...

Страница 23: ...board icon Leakage Problem Uneven liquid levels among the tips dripping from tip s even when empty or dispense commands are not in use Solution Make sure there are no foreign objects between the core...

Страница 24: ...ssure research success SPT Labtech products are renowned for their industry leading reliability and efficiency With our reliance service you have access to a dedicated support team to safeguard your i...