Example 2
SPROG 3 and SBOOST with separate power supplies.
Using a SPROG 3 and SBOOST in this way is not recommended.
A short circuit in the SPROG 3 power zone will affect the DCC signal to the
SBOOST.
Each power supply should be the same voltage.
Each power supply must be able to supply the full rated current, at least 2.5
Amp.
A common ground connection is required between the power supplies.
Power districts must be separated by isolation gaps in both rails.
Isolation Gap
Power
Power