SprintRay ProWash S Скачать руководство пользователя страница 2

3

Plug in and Connect to Network

4

The Basics

MAX

Use the provided power adaptor and cable to plug your 
ProWash S into a surge protector or uninterrupted power 
supply. Flip the switch on the back to the ‘On’ position.

On startup, ProWash S will prompt you to connect to a 
network. You can join an existing Wi-Fi network using the 
touchscreen or use an ethernet cable. Maintaining an 
internet connection will allow ProWash S to receive updates.

If you need to reset your ProWash S, switch it off and then 
unplug the power cable, wait 30 seconds, then plug it back in.

Wash Chamber

This chamber is where parts are 
cleaned and dried. You can wash 
parts directly on the SprintRay build 
platform or remove and wash them 
in the basket. IPA will automatically 
pump in and out of the wash 
chamber from the IPA tanks. 

Never pour IPA directly into 
this chamber; it should only 
be poured into the tanks

Failure to replace IPA when a hydrometer 
floats will void your warranty

IPA Tanks

Pour IPA directly into these tanks. Each tank 
has a maximum capacity of 2 liters. 

Tank 1

The IPA in this tank is used for the bulk wash, 
so it will need to be changed more often.

Tank 2

The IPA in this tank is used for rinsing, so it 
will not need to be replaced as often. It can be 
recycled into tank 1 for extended life.

Drain Ports

Each tank has a drain port designed to mate with the drain 
hose attached to the back of the machine. Refer to Section 8 
for instructions on how to drain.

Hydrometers

Over time, the IPA in ProWash S will become saturated 
with uncured resin and lose its cleaning effectiveness. 

The hydrometers are precalibrated to measure resin 
saturation and will float when it is time to replace IPA.

Submerged Hydrometer = IPA Okay

When a hydrometer is submerged, the IPA in the 
tank is acceptable and ready for use.

Floating Hydrometer = Replace IPA

A floating hydrometer indicates that IPA has 
become saturated with resin and will no longer 
effectively wash your prints. Drain the tank, clean, 
and fill with clean IPA.

Power Switch
Power Port

Drain Ports

Drain Hose

Touchscreen

Содержание ProWash S

Страница 1: ...aning Brush Section 9 Basket Section 7 Hydrometers Pre installed Section 4 Power Cable USB Cable Section 12 Wash Filter Sections 2 9 Metal Tweezers Section 10 Power Adaptor Magnet Sticker Section 6 Bu...

Страница 2: ...loats will void your warranty IPA Tanks Pour IPA directly into these tanks Each tank has a maximum capacity of 2 liters Tank 1 The IPA in this tank is used for the bulk wash so it will need to be chan...

Страница 3: ...before sinking Depending on which SprintRay 3D printer you have you may need to attach a magnet and or use a fitment adaptor when using ProWash S How to Install the Magnet If using Pro95 or Pro55 you...

Страница 4: ...print batches Dense supports Complex geometries Recommended for Models shorter than 4 Solid models Models for aligners Surgical guides Night guards Do not stack models or crowd them together as this...

Страница 5: ...n the drain Used IPA should be properly disposed of through a hazardous materials collection as required by local laws and regulations WARNING For best results clean the tanks every time you refresh I...

Страница 6: ...mpany The secondary mesh below the removable filter should never be removed WARNING ProWash S has a mesh filter that protects the plumbing from resin and other debris The filter should be cleaned when...

Страница 7: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inte...

Отзывы: