background image

Installation

• 

Ensure mechanically secure fi xings are in use as recommended.

• 

Ensure cooling airfl ow around the product is as recommended.

• 

Ensure cables/wire terminations are as recommended and are torqued correctly.

• 

Ensure the product rating is correct - do not exceed the rating.

Application risk

Electromechanical safety is the responsibility of the user. 

The integration of this product 

into other apparatus or systems is not the manufacturer's or distributor of the product's 

responsibility. It is the user's responsibility to ensure the compliance of the installation with 

any regulations in force.

Health and safety at work

Electrical devices can constitute a safety hazard. 

Thorough personnel training is an aid 

to SAFETY and productivity. SAFETY awareness not only reduces the risk of accidents and 

injuries in your plant but also has a direct impact on improving product quality and costs. 

If you have any doubts about the SAFETY of your system or process, consult an expert 

immediately. Do not proceed without doing so. If in doubt, refer to the Supplier.

CAUTION!

 

EQUIPMENT DAMAGE HAZARD

 

• 

We thoroughly test our products. However, before installation and start-up, 

inspect all equipment for transit damage, loose parts, packing materials, etc.

• 

Installation must observe the required environmental conditions for safe and 

reliable operation.

• 

In a domestic environment, this product may cause radio interference, requiring 

adequate measures to be taken.

 

Obtain the permission of the supply authority 

before connecting to the low voltage supply.

WARNING!

 

PERSONAL INJURY AND/OR ELECTRICAL SHOCK HAZARD

• 

Always isolate all power supplies from the equipment before starting any work.

• 

Never perform high voltage resistance checks on the wiring without fi rst 

disconnecting the product from the circuit under test.

• 

Use guarding and additional safety systems to prevent injury and electric shock.

• 

Metal parts may reach 90°C during operation.

Hazards

This equipment can endanger life through rotating machinery and high voltages.

WARNING!

 

Only qualifi ed personnel must install, operate and maintain this equipment. 

A qualifi ed person is someone technically competent and familiar with all safety 

information, established safety practices, installation, operation, maintenance 

and the hazards involved with this equipment and any associated machinery.

General risks

Содержание Option CON113

Страница 1: ...HG105408EN00 Issue 1 01 2022 World Class Design World Class Function 30 Years Expertise in Industrial Motor Control Product Manual BUFFER BOARD Option CON113 ...

Страница 2: ...rs and operators understand the included WARNINGS CAUTIONS and NOTES which alert the user to safety issues COMPLY WITH WARNINGS AND CAUTIONS AT ALL TIMES Each of these carries a special meaning and should be read carefully WARNING A WARNING is given when non compliance with the warning may result in personal injury and or equipment damage CAUTION A CAUTION is given when non compliance with the cau...

Страница 3: ...UIPMENT DAMAGE HAZARD We thoroughly test our products However before installation and start up inspect all equipment for transit damage loose parts packing materials etc Installation must observe the required environmental conditions for safe and reliable operation In a domestic environment this product may cause radio interference requiring adequate measures to be taken Obtain the permission of t...

Страница 4: ...lth and Safety at Work Devices constitute a safety hazard It is the responsibility of the user to ensure compliance with any Acts or By Laws in force ONLY skilled persons should install this equipment Disposal This product contains materials that are consignable waste under the Hazardous Waste Regulations 2005 Metal and plastic materials can be recycled however disposal of the printed circuit boar...

Страница 5: ...intain dancer position Features Specification Mains powered Supply voltage 110 or 240 Vac Adjustable response rate Dimensions W 96 mm H 100 mm D 45 mm Internal preset and externally adjustable references 10 0 10 V feedback input and output Fully isolated circuit Follow these installation instructions and the drive s Product Manual to maintain EMC compliance Further measures may be necessary EMC be...

Страница 6: ...ensions 10K AC POWER IN 110 V or 230 V ANTI CLOCKWISE MID WAY CLOCKWISE Terminals 1 6 Terminals 7 12 Terminals 19 24 Terminals 13 18 OFFSET SCALE RAMP RATE CH3 CH4 CH5 ON 90 mm 86 mm 5 mm 5 mm Fixing screws M4 x 20 mm J1 J2 B C D A T9 INTEGRATOR PRESET INPUT E G OUTPUT Z1 Z2 2 Installation 2 2 Installation Installation WARNING ELECTRIC SHOCK HAZARD Disconnect the mains supply before working on the...

Страница 7: ...nnel information 3 3 Channel information Channel information Channels Default operating mode CHANNEL 1 Differential amplifier having unity gain Fit extra resistors to the board to change the gains CHANNEL 2 CHANNEL 3 Integrator circuit OFFSET Use to zero integrator drift usually set mid way unless factory preset and sealed preset SCALE Set TOTAL GAIN K2 A CHANNEL 4 Summing amplifier OFFSET Use as ...

Страница 8: ...DIFFERENTIAL AMPLIFIER CHANNEL 3 SCALE OFFSET preset CHANNEL 4 SCALE OFFSET CHANNEL 5 RAMP RATE DANGER ELECTRIC SHOCK RISK 470K Z2 Z1 100K 4M7 0 1 µF 100R J2 100K 100K 100K 10K 100K 50K 50K 12 12 cw for ve OFFSET SCALE cw to reduce gain IC2 100K close to preset integrator input to integrator output OFFSET PRESE internal refere offset 10K external reference pot AC POWER IN 110 V or 230 V 1 µF 47K 4...

Отзывы: