11
Terminal descriptions
5
5 Terminal descriptions
Terminal descriptions
WARNING!
PERSONAL INJURY AND/OR
EQUIPMENT DAMAGE HAZARD
Never work on any control equipment without first isolating all power supplies.
You MUST provide protection by fitting a correctly rated fuse upstream of the
drive.
Control cable
1.5 mm
2
DC+/DC-, A+/A-
Use correctly rated cable suitable for 1.5 x armature current
External control options:
Speed setpoint from external 10 kΩ potentiometer
TERMINALS -
tightening torque: 0.5 Nm (4.4 lbf.in)
The control terminals are all referenced to the negative dc supply to the drive (dc-).
All interface signals must be referenced to the same potential.
1
+10 V Reference
2
-SP Inverting speed input
3
+SP Non-inverting speed input
4
+5 V Reference
5
Common electronics 0 V. Also on T6
6
V- Negative dc power supply input
7
V+ Positive dc power supply input
8
A+ Armature connection
9
A- Armature connection
5
6
7
1
2
3
4
9
8
0 V
0 V
READY
F2
F1 V+
A+
MAX
5 mA, 10 V
5 mA, 5 V
FB
IR COMP
A-
V-
Figure 17 200XLV block diagram