MAINTENANCE AND TROUBLESHOOTING
Although transmitters SST7X do not require a maintenance on periodical basis, it is good
practice to regularly check the general transmitter status, the possible presence of rust or
damage on the case or on the measuring diaphragm and the presence of clogging in the process
connection. At the end of 10 years, the equipment must be subjected to a check of integrity of
the components, through the thickness check and the hydrostatic test.
P
ROHIBITION
!
Repair, maintenance and/or overhaul of the equipment shall only be conducted by
the manufacturer himself, or by a repairer he has qualified or authorized.
Is forbidden during the maintenance operation to use the
instrument as a handle or step.
Please refer to the following pages scheme for troubleshooting.
In any case contact our technical department for help.
Condition
Potential
source
Solution
The transmitter
doesn’t turn on
Supply
Check the supply voltage to be 12.5Vdc <V
supply
<30Vdc.
Polarity
Check the transmitter connection polarity.
Electrical load Check that the load is less than the maximum allowed.
Measure is
incorrect
Process
Accurately verify the compatibility between the process
and the connection type.
Sensor drift
Apply zero input conditions to the transmitter and use
the OFFSET command.
EMC
interference
Accurately verify the possible presence of
electromagnetic interference on the supply line. Check
the PE connection.